User Manual

16/49
Siemens ET D1 · 2018/2019
16
Technical Information
Shutter/Blind Controls
Ceiling movement detector 360º (
5TC7220-0 / 5TC7220-1)
Power supply AC 230 V, 50 Hz
Power consumption
<1 W
Contact load
16 A, cos ϕ = 1
Incandescence or halogens 230V
3000 W
Halogens electronic transfo
2400 W
Halogens ferromagnetic transfo
3000 W
Fluorescence
1300 W (130 μF)
PL lamps
18 x 7 W, 12 x 11 W, 10 x 15 W, 10 x 20 W, 10 x 23 W
LED lamps
Detection angle Circular 360º
Range of coverage
Ø 7 m at 2,5m high and 18 ºC
Settings
Via potentiometer
Lux value
5 ... 1200 Lux
Time delay
6 seconds to 12 minutes
Mechanical specifications
Dimensions (mounted) 118,5 x 45 mm
Electrical safety
Degree of proteccion IP40, Class II
Environmental
specifications
Working temperature -10 ... +45 °C
1)
For the flushmounting version a 65mm Ø box/hole is needed.
Maximum sensitivity zone
Ø3m
Ø7m
2,5m
Technical specifications
Schematics