Shutter/Blind Controls
Shutter/blind key-operated switches, for master-key systems
Overview
All prole semicylinders must comply with DIN 18252 with
approx. 40 mm overall length. Examples:
Bit is in neutral position.
The key-operated switch is ideal for use in main and general
master-key systems.
In the case of special requirements and existing systems or cus-
tom-made tumbler arrangements for master-key systems, the
lock barrels must be obtained from a specialist dealer.
Schematics
Make Name
CEC
No. 8511/2 (as PH 22)
BKS
No. 3101
Wilka
No. Z 1411 12h
Zeiss Ikon
No. 1600044 = mv
P
5TA7668
5TA7680
P P
5TA7670
5TA7681
M1
N LPE
M1
N L
M2
I2_12167
Maintained
contact
Maintained
contact
Maintained
contact
Maintained
contact
1-pole
2-pole
1-pole
2-pole
Up
Down
0 position
Up
Down
Up
Down
PE