User Manual
16/56
Siemens ET D1 · 2018/2019
16
Technical Information
Shutter/Blind Controls
sys shutter/blind control inserts (5TC1231)
Schematics
Sample connection
Application options
Example 1:
Shutter/blind control with conventional extension units
When using the shutter/blind pushbutton (5TA2114), the
shutter/blind can be manually moved to the required position
(UP/DOWN or STEP command). The number of connectable
conventional extension units is unlimited.
Example 2:
Group control with 2 motors and central operating point
Together with the UP 211 wave shutter/blind pushbutton inserts,
the sys shutter/blind control insert is implemented as a central
operating point. The inserts and individually control the
respective shutter/blind motors M ( and ). The time values
stored in the UP 211 wave shutter/blind pushbutton
(e.g. 8:00 UP and 20:00 DOWN command) allow the time-
controlled stopping and starting of all connected motors.
Caution:
• It is not permissible to use a shutter/blind control sys insert as
the central op
erating point an
d directly operate a shutter/blind
motor.
• When protecting the central operating point against short cir-
cuit using a separate residual current operated circuit breaker,
both circuits must be isolated in order to prevent inadvertent
tripping of the circuit breaker.
Example 3:
Integrating a wind alarm
The indicator for the wind alarm is integrated in the shutter/blind
control over the extension unit input. In the event of a wind alarm,
the shutters/blinds are raised and locked in that position until the
wind alarm is reset over the indicator. As long as the interlock is
enabled, neither manual nor automatic operation of the shutters/
blinds is possible.
L
5TC1 231
PE
N
L
6
1
2
I2_08611
N
IN
M
3
M
1
~
5
7
4
1
2
3
4
5
6
7
Neutral conductor
Secondary input UP
Secondary input DOWN
Motor UP
Motor DOWN
External conductor connection
Interface (230-V-PEI)
230 V AC ~
L
5TA2 114
L
5TC1 231
I2_08612a
N
IN
PE
N
L
1 2
M
1
~
M
230 V ~
AC
2
L
5TC1 231
I2_08613
N
IN
M
M
5
L
5TC1 231
N
IN
M
M
4
1
L
N
IN
M
4
3
PE N L
AC 230 V ~
1
2
3
4
5
5TC1 231