Technical Information
Shutter/Blind Controls
Shutter/blind controls
16
Overview
Form of delivery for the shutter/blind control
Product features:
Easy operation via a 4-button eld
Switching time block Mo to Fr: 1 x UP, 1 x DOWN
Switching time block Sa to Su: 1 x UP, 1 x DOWN
Quick conguration function
Factory-congured switching times
Reserve power > 6 h over storage capacitor
Also congurable with an unlocked shutter/blind control insert
without extension unit input
After approx. 30 min, the storage capacitor for the reserve
power is completely recharged.
Design
The shutter/blind control insert is mounted in a DIN 49073-
compliant device box (recommendation: deep box).
The terminals of the insert must be directed downwards.
The shutter/blind clock is plugged with the frame onto the
insert.
The electrical contacting is achieved over the plug .
Programming
With a charged storage capacitor, the control remains congu-
rable for approx. 6 h even with the insert released.
The following factory-preset switching times are stored in the
memory:
Switching time 1: 07:00, Mo. to Fr.
Switching time 2:
20:00, Mo. to Fr.
Switching time 3: 09:00, Sa. to Su.
Switching time 4:
20:00, Sa. to Su.
The current time can be accepted as switching time for the
memory by pressing the desired direction of travel (
or
) and
then activating the "Prog" button. The present switching time is
overwritten in this case.
Effect of the length of the button stroke:
Short keystroke (< 1 s): jog mode for adjusting the slats on
shutters/blinds
Long keystroke (> 1 s):
2 min continuous operation, can be stopped with pushbutton
or
.
Schematics
I2_08784
LN
Motor
PROG
Mo Di Mi Do Fr
Sa
So
MAN
AUTO
PROG
Mo Di Mi Do Fr
Sa
So
MAN
AUTO
Shutter/blind
clock
Shutter/blind
control insert
Shutter/
blind control
1
2
1
2
3
4
3
4
I2_08786
Shutter/blind control insert
Shutter/blind clock
Frame
Plug
L
N
N
L
AC 230 V ~
I2_08785
PE
M
1
~
Motor
1
3
4