User Manual

2/19
Siemens ET D1 · 2018/2019
i-system
Shutter/blind controls
2
Version Order No.
5TC1520
Shutter/blind controls
For controlling a blind or shutter motor with mechanical or electronic
limit switches
Operation is by means of 4 control buttons
Versions
Titanium white (similar to RAL 9010) 5TC1520
Electrical white (RAL 1013) 5TC1532
Aluminum metallic (similar to RAL 9006) 5TC1522
Carbon metallic (similar to RAL 7016) 5TC1524
Note Section Page
For Technical specifications, see ... Technical Information /
Shutter/ Blind Controls /
Shutter/ blind controls
16/57
Note
Download the operating and mounting instructions from:
http://support.automation.siemens.com/ww/view/en/5tc1520/all
Product features
5TC1521
Note
Titanium white (similar to RAL 9010) 5TC1521
Aluminum metallic (similar to RAL 9006) 5TC1523
Carbon metallic (similar to RAL 7016) 5TC1525
Note Section Page
2/35 5TC1526
16/58
Note
Product features
Flush-mounting device without an extension unit input
230 V AC, 50 Hz (N conductor required)
For screw and claw fixing
Type of connection: screw terminals
2 relays which are electrically interlocked against each other with a
minimum switchover time of approx. 1 s
Bridging of voltage interruptions < 0.2 s
Connected load: max. 1 motor up to 1000 W
Pulse duration: Approx. 2 min
Accuracy: ± 1 min per month
Reserve power: > 6 h
S
witching times: max. 4 (in 2 blocks: Mo ... Fr / Sa ... Su)
Factory preset switching times for fast
er commissioning
Possible reset to factory settings
Manual operation possible at any time
Comfort shutter/blind controls
For controlling a blind or shutter motor with mechanical or electronic
limit switches and comprehensive functionality (see product features)
Menu-controlled operation by means of 4 control buttons
The sun sensor must be orde
red
separately, see ...
Accessories and spare
parts
For Technical specications, see ... Technical Information /
Shutter/Blind Controls /
Comfort shutter/blind
controls
Download the operating and mounting instructions from:
http://support.autom
ation.siemens.com/ww/view/en/5tc1521/all
Flush-mounting device without an extension unit input
230 V AC, 50 Hz (N conductor required)
For screw and claw fix
ing
Type of connection: screw terminals
2 relays which are electrically interlocked against each other with a
minimum switchover time of approx. 1 s
Bridging of voltage interruptions < 0.2 s
Connected load: max. 1 motor up to 1000 W
Pulse duration: 2 min factory setting, may be changed to
as much as 12 min by programming
Accuracy: ± 1 min per month
Reserve power: approx. 24 h
S
witching times: max. 18 (can be split up in
three memories)
Factory preset switching times for faster commissioning
Possible reset to factory settings
Random generator ± 15 min
Astro program (can be delayed by ± 1 h 59 min)
Easy changeover to daylight savings
Twilight and sun protection function is possible with an optional sun
sensor
The random and astro functions can be combined
Manual operation possible at any time