User Manual

2/20
Siemens ET D1 · 2018/2019
i-system
Shutter/blind controls
2
Version Order No.
5TC1270
5TC1270
5TC1271
5TC1271
Shutter/blind control flush-mounting isolating relays
Double, with individual control
Relay for the control of several shutters or blinds
Two motors can be controlled per isolating relay, even if further isolat-
ing relays are connected downstream
Option for individual control of connected motors over shutter/blind
pushbutton (e.g. 5TA2 114)
The isolating relay is to be installed into a surface-mounting or ush-
mounting box (ush-mounting box from 70 mm or surface-mounting
boxes from 100 mm x 100 mm)
Only for in-phase operation
8 A (AC-1) or 3 A (ind.), 230 V AC, 50 Hz
58 mm
x 59 mm x 22 mm
Note Section Page
For Technical specications, see ... Technical Information /
Shutter/Blind Controls /
Shutter/blind control
ush-mounting isolating
relays
16/62
Note
Download the operating and mounting instructions from:
http://support.automation.siemens.com/ww/view/en/5tc1270/all
Shutter/blind control flush-mounting isolating relays, compact
Relay for the control of several shutters or blinds
A maximum of two motors can be connected per compact isolating
relay, whereby the drive connected to the marked motor terminals can
also be individually controlled over a shutter/blind pushbutton
If cascaded, a motor can be connected to each compact isolating
relay, which can also be individually controlled over a shutter/blind
push
button
The isolating relay is to be installed into a surface-mounting or ush-
mounting box (ush-mounting box from 60 mm , 40 mm deep or
surface-mounting boxes
from 75 mm x 75 mm)
Only for in-phase operation
8 A (AC-1) or 3 A (ind.), 230 V AC, 50 Hz
50 mm x 53 mm x 22 mm
Note Section Page
For Technical specications, see ... Technical Information /
Shutter/Blind Controls /
Shutter/blind control
ush-mounting isolating
relays, compact
16/63
Note
Download the operating and mounting instructions from:
http://support.automation.siemens.com/ww/view/en/5tc1271/all