Technical data

26
1054I-02.FM
Gigaset 1054 isdn, GBR: A30853-X200-B101-51-7619
10.06.1999
Installation Non-Cordless Devices
The base station Gigaset 1054isdn has two telephone sockets (B and C) that are available for
non-cordless end user devices. The connection sockets are automatically assigned internal call
numbers:
Socket B (top) has the internal call number 0
Socket C (bottom) has the internal call number 9
The connectors for the accessory equipment must have TAE plugs. The sockets of the Gigaset
1054isdn have the coding F/N.
Only certified non-cordless devices may be connected.
A telephone can be connected and used immediately without any additional settings. The tele-
phone, or non-cordless device doesn’t have to be registrated at the base station.
The dialing mode (pulse or tone) is recognized automatically and doesn’t need to be set manu-
ally. It is not possible to establish a connection with two non-cordless devices at the same time.
The signal key on the telephone key pad will not function once the telephone is connected to
Gigaset 1054isdn (Exception: Telephones with tone dialing).
The charges are not displayed on the telephone. However, the accumulating costs of each call
are recorded by the system. The charges for each subscriber and each multiple number can be
queried or deleted from a registrated mobile unit.
Using one of the registrated mobile units you can define the necessary settings for the additional
device connection.
You can stipulate whether you want to connect a fax machine, modem, BTX, an intercom or an
answering machine (see page 74 or page 134).
You can also define additional subscriber specific settings, for example, trunk authorization, ring
allocation, etc. using a registrated mobile unit.
When using a fax machine on Gigaset 1054isdn, you will need to set the fax machine for
operation behind a telecommunication installation (see the User’s Guide for your fax
machine).
You can use the following data transfer speeds on the subscriber connections:
Socket B (top), internal call number 0: up to 28,800 Baud
Socket C (bottom), internal call number 9: up to 9,600 Baud
Connector Socket
The following can be connected Internal call number Registrate on system as
Telephone (socket B or C) 0 or 9 Telephone
Answering machine (socket B or C) 0 or 9 Telephone
Fax machine (socket B) 0 Fax or “Neutral“
Modems (socket B) 0 Modem
T-On-line (BTX) devices (socket B) 0 Modem
External clock (socket B or C) 0 or 9 Telephone
Intercom (socket C) 9 Intercom
Connecting Telephones
Connecting Non-Cordless Devices (other than telephones)