*LJDVHW 0 'DW D The cordless USB interface for connecting PCs to Gigaset 3070/75isdn +RZ WR XVH WKLV PDQXDO Operating Instructions Note Please read the safety precautions outlined in these operating instructions before putting the unit into service! &RQWHQWV ,QGH[
+RZ WR XVH WKLV PDQXDO The following controls are available in Acrobat Reader or in the context menu (right mouse button): Click here when you see this hand. Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 What is a Gigaset M101 Data? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Meaning of "local adapter" and "remote adapter" . . . . . . . . . . . . . . . . . . . . . . . .
Overview Front 1. Operating LED, illuminated when power supply is active, see "LEDs" on page 20 2.
Contents Contents How to use this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 What is a Gigaset M105 Data? . . . . . . . . . . . . . . . . . .
Contents Tips&tricks, settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Access to different V.24 terminals from a laptop: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Sequential access from multiple computers to a terminal: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 PC-PC direct cable connection: via RS232/V.24 interface . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction Introduction What is a Gigaset M105 Data? Your Gigaset M105 Data is a cordless USB interface for operation at the Gigaset 3070/75isdn base station, at a second Gigaset M105 Data or at a Gigaset M101 Data (V.24 interface). A Gigaset M105 Data unit is powered via the USB port but operates like a COM interface with regard to data.
Introduction Meaning of "base" and "portable part" This is an assignment in the DECT connection (Base FP = Fixed Part, PP=Portable Part) and refers exclusively to the air interface. A base is the same as a base station in Gigaset telephony. Here, portable part is the same as handset. This is defined, for example, through the registration option. Only one Gigaset M105 Data "Portable part" can have an active connection to a Gigaset 3070/75isdn or a Gigaset M101/M105 Data "Base".
Introduction Installation Prerequisites for installation For installation, you need: z an IBM-compatible PC with the following configuration: – Windows 98 operating system – approx. 5 MB free hard disk memory – 1 free USB slot activated in the PC’s BIOS – CD-ROM drive, z the CD-ROM containing the installation program Installing 1. Switch on the PC. 2. Insert the CD in the CD-ROM drive. 3. Connect the USB port on the Gigaset M105 Data to the USB interface on your PCs by means of the USB cable provided.
Configuration Configuration The purpose of configuration is to register the Gigaset M105 Data unit at a Gigaset 3070/3075isdn base station, at a second Gigaset M105 Data or at a Gigaset M101 Data. You can only perform configuration with the configuration program. Registering Gigaset M105 Data at Gigaset 3070isdn/ 3075isdn Proceed as follows: 1. Install Gigaset M105 Data. 2. Switch Gigaset 3070/3075isdn to registration mode (press LED). 3. Start the Gigaset M105 Data configuration program. 4.
Configuration Registering Gigaset M105 Data at Gigaset M105 Data Proceed as follows: 1. Connect both Gigaset M105 Data units to a PC. 2. Start the Set Gigaset program at both PCs. 3. Select the Local adapter tab at both PCs. 4. Change the type of Gigaset M105 Data at one of the PCs from "Portable part" to "Base". 5. Click the Register button at both PCs. At the PC connected to the "Base" type Gigaset M105 Data, a LED flashes in sequence to signal that the unit is ready for registration.
Configuration Registering Gigaset M105 Data at Gigaset M101 Data Proceed as follows: 1. If the M101 is not already in the default status, please ensure that the M101 is operating as a "Base". Please refer to the configuration program for the type display and the switch options. 2. Press and hold down the black button on the Gigaset M101 Data (Base). After approx. 10 seconds, the LEDs indicate that the system is ready for registration by flashing in sequence. 3.
Configuration program options Configuration program options General You will not need the majority of configuration options for the simple implementation of a Gigaset M105 Data unit downstream of a Gigaset 3070/ 3075. Starting the configuration program Under Start, select Programs followed by Gigaset M100 Data and finally Set Gigaset.
Configuration program options "Connection" tab Upper section: connecting to the PC You can set the virtual COM port at which the local adapter is connected in the upper section of the tab. We recommend leaving the option No automatic detection at program start-up deactivated (as shown). The program then checks the existing COM ports and determines where the adapter is connected. Manual interface selection is only recommended if there is more than one Gigaset M105 Data unit connected to the PC.
Configuration program options "Operating mode" tab Important: The "Operating mode" tab is not active if the registered Remote adapter is a Gigaset 3070/75isdn. In this case, no settings can be made in this tab. If one of the adapters is set to "AT commands (PC)" or "AVM compatible (PC)", the other adapter must switch to the corresponding operating mode "AT commands (device)" or "AVM compatible (device)".
Configuration program options Special settings for "Direct connection" mode In Direct connection mode, the fields in the lower section of the dialog box are activated: you can set the transmission parameters for the virtual COM port at the PC. Use the default settings if you do not want to change any other parameters. In the event of malfunctions, reduce the speed in the Bits per second field. Set your communication software likewise to this value.
Configuration program options fLocal flow control check box Local flow control normally does not have to be activated except when operating low-memory V.24 terminals (in connection with Gigaset M101 Data). Activating local flow control can help in the event of data transmission problems (e.g. sending faxes, operating a serial printer). When local flow control is active, the Gigaset M105 Data unit connected to the V.
Configuration program options "Local adapter" tab Changing the name The purpose of adapter names is to provide a rapid overview. The local adapter must be called "PC". The remote adapters should, if possible, be named after the peripheral device connected, e.g. "3070/3075isdn" or "Modem". Adapter names can be changed by entering or changing a name in the Name field. Names can contain letters and digits as well as blanks. The name must not contain more than 20 characters.
Configuration program options Registering a portable part Both adapters are powered. The Gigaset M105 Data unit is connected to the PC; start the "Set Gigaset" program. Select the Local adapter tab. The following dialog box appears: Up to six registered devices can be entered in the Registered adapter window. Depending on the adapter type of the local adapter, Registered adapter or Registered bases is displayed. Select a registration location and click Register.
Configuration program options Enter the PIN and click OK. The portable part now searches for the base station and automatically registers at it. If registration is not possible (base station not in registration mode or not powered, incorrect PIN), the system will indicate the necessary steps for resolving this problem. De-registering a portable part Select the adapter in the window and click Unregister. Automatic enabling The automatic enabling feature is not available with Gigaset3070/75isdn.
Configuration program options "Remote adapter" tab This tab is used for configuring the Remote adapter that is not connected to the PC. Registration must be performed first so that the two Gigaset M105 Data units can communicate. The Remote adapter tab is only available after registration on the Local adapter tab.
Configuration program options Changing the name As for local adapter, see "Changing the name" on page 15. Change PIN ... Click Change PIN .... Enter the old PIN (PIN: 1–8 digits, default: 0000) to obtain authorisation to change the PIN and press the tab key. Enter the new PIN and press the tab key. Enter the new PIN in the Repeat new PIN field and click OK. The PIN is changed if the new PINs entered are identical and if the correct old PIN is entered. Otherwise, a warning appears.
Configuration program options LEDs There are two LEDs on the front of the Gigaset M105 Data unit. LED 1: Gigaset M105 Data status LED 1 indicates stand-by mode: LED 1 flashes slowly The adapter is searching for the partner or has not been registered. LED 1 flashes quickly The partner was found, the data connection is not assigned to the transmission route. LED 1 is constantly lit The partner was found, the transmission route is on stand-by.
Configuration program options Notes on installation and operation Place of installation There must be a 220/230 V AC and 50 Hz power socket nearby. The Gigaset M105 Data should not be installed in the immediate vicinity of other electronic devices, such as hi-fi systems, office equipment or microwave ovens, otherwise there is a risk of mutual interference. Place the Gigaset M105 Data unit on a level, non-slip surface. The device feet do not leave any unsightly marks.
Configuration program options Why set an operating mode? Technical background Configuration is always performed for both data modules on connection link. In the case of registration at a Gigaset 3070/3075isdn, the transmission parameters are set automatically; apart from the assignment of a name, no other settings are necessary. Special features when connecting two Gigaset M105 or M101 Data units A Gigaset M105 Data unit is powered via the USB port but operates like a COM interface with regard to data.
Configuration program options There are five possible operating modes for every Gigaset M101/M105 Data: 1. Direct connection: this operating mode is implemented for all devices that are not controlled with AT or AVM-compatible commands 2. AT commands (PC) or AVM compatible (PC): this is the operating mode for the local adapter. The Gigaset M105 Data unit determines the conditions on the serial interface in the same way as a modem.
Tips&tricks, settings Tips&tricks, settings This section describes settings, implementation options and programming methods. Access to different V.24 terminals from a laptop: z All terminals (PC, modem, Gigaset 3070/3075isdn) can be accessed from a laptop. z Only one data connection at a time can ever be set up to a terminal. z You must select the relevant connection partner in the configuration mask in order to switch between the various terminals.
Tips&tricks, settings Sequential access from multiple computers to a terminal: z Multiple portable parts (PC, laptop) share a Gigaset 3070/3075isdn base (modem). z Only one data connection at a time can ever be set up from a "portable part to the terminal". z Simultaneous access from both portable parts to the Gigaset 3070/ 3075isdn modem is not possible. z The data connection is automatically enabled if the data line is not accessed.
Tips&tricks, settings PC-PC direct cable connection: via RS232/V.24 interface The problem that often occurs with PC-PC direct cable connection is incorrect baud rate setting. The following section describes the configuration of a PC-PC direct cable connection at a Win95 system (similar for WIN98). Before using the actual Gigaset M105 Data unit, application functionality should be checked using a direct connection (with a null-modem cable).
Tips&tricks, settings Then set the port speed: The baud rate (max. 115200) and HW handshake (default setting) are set in this mask. If you can now transfer data from one PC to another, proceed with the second step. 2. Set the direct cable connection parameters Exit the terminal program at one of the PCs. Under the Win95 Start menu, select Settings > Control Panel and open the window Control Panel window. Double-click the System icon (you should now see the System Properties window).
Tips&tricks, settings Double-click the icon to expand the branch. The setting Null-Modem Cable at COMx should be available. Select the appropriate COM port for your configuration and double-click it to open another subfolder.
Tips&tricks, settings This Modem tab contains the setting for the maximum speed. This should be set to 115200 bps. Activate Hardware under Use flow control in Connection > Advanced. Click OK to exit each window. 3. Test the baud rate setting Open the direct cable connection program under Start > Programs > Accessories. If this icon is missing, you may have to reinstall the appropriate software from the Win 95 system CD.
Tips&tricks, settings Select Change and activate Guest. Then enter the interface, e.g. NullModem Cable at COM 1. To enable access by the other PC, the host (controlling party) and guest (accessing party) as well as the file and print sharing option must be activated.
Tips&tricks, settings Click File and Print Sharing in the sub-window. Set the parameters here. If a change was made, new drivers are loaded and Windows must be restarted. If file and print sharing was already activate, the computer does not need to be restarted. Otherwise, restart your computer.
Tips&tricks, settings If the system was not restarted, the following window appears: If file/printer sharing has not yet been activated, start to activate it, see "Sharing files" on page 33. In the final window, select Finish and click OK to answer the questions. A window entitled Direct Cable Connection with the status Accessing %1!s should now appear. The message CLIENT should appear a number of times in the terminal program of the connected computer.
Tips&tricks, settings Sharing files Since the Windows information in the previous mask is somewhat confusing, and since no references are made to the File Manager/Explorer, here is the correct procedure. Once file sharing has been activated and the PC restarted, you can release files for processing by the other PC via the File Manager/Explorer. Start the Explorer: Select the relevant folder and the click File1 > Properties.
Tips&tricks, settings Assign the other PC user access rights to the files on your hard disk, or where applicable, activate password protection. Files that support sharing are identified as follows: shared not shared Examples of PC-PC direct cable connection problems Other modem drivers installed continue to operate at the same COM port (special ISDN TA drivers, CAPI modem drivers or similar software are often the cause of the problem).
What happens if... What happens if... If a malfunction occurs, check the following points: z The USB cable connections to the connected devices are fully inserted. z The adapters are not too far apart and there are no large parts of buildings in between (see "Place of installation" on page 21). z Registration was successful. When operating Gigaset 105 Data with Gigaset 101 Data: z The local adapter operating mode is set to AT commands (PC) or AVM compatible (PC).
What happens if... Support Updates and news on the Internet www.siemens.com/pc-communication-support Notes on sending faxes directly from the PC You may encounter problems if your PC program uses Class 1 fax mode. Class 1 does not support signal runtime delays which are required for switching to radio mode. Class 2 mode, on the other hand is less sensitive. Nevertheless, interference can still occur here due to a bad radio link.
What happens if... Configuration management Fault Cause Solution Message from configura- The COM port used is being tion program: "Data adapt- used by another program. er not found..." Close the application that is using the COM port. Message from configura- The base station may not have tion program: Registration been ready for registration or not possible. the radio connection was temporarily affected by "external influences". Repeat registration with a base that is ready.
What happens if... Fault Cause Solution The modem parameter request function is not working or is not correct. Windows does not follow the AT Hayes conditions. Data transmission with Xmodem is very slow. Xmodem operates in half-du- Use another transmission protocol, plex mode. The transmitting e.g. Zmodem. unit waits for acknowledgement after each data package. The signal delay (20–30 ms per data block at the DECT interface) significantly reduces the transmission speed. Laplink 7.
What happens if... Technical data DECT =Digital Enhanced Cordless Telecommunications Number of channels: 120 duplex channels Standard: Radio frequency range: 1880 MHz to1900 MHz Transmitted power: 10 mW, average rating per channel Range: up to 300 m outdoors, up to 50 m indoors Power supply: USB powered Power consumption: Permissible ambient conditions for operation: Stand-by mode: approx. 4 W Data transfer mode: approx.
What happens if... Safety precautions Medical equipment can be affected by DECT devices. Gigaset M105 Data can cause unpleasant humming in hearing aids. Do not install Gigaset M105 Data in bathrooms or showers. Do not operate Gigaset M105 Data in environments where there is risk of explosion. Do not forget to include the operating instructions and CD when passing on Gigaset M105 Data to a third party. Gigaset M105 Data is designed for operation in your country as indicated on the back of the unit.
Index Index Numerics Flow control 3070isdn/3075isdn 7 14 H A Hardware (RTS/CTS) 13 Adapter type, changing 15 Ambient conditions 21 AT commands 12 AT commands or AVM compatible Automatic enabling 17 I 23 Implementation options 24 Initial configuration 7 Installation 6 B L Base 5 Baud rate, setting Laplink 7.
Index T PIN, changing 19 Place of installation 21 Portable part 5 Program, installing 6 R Registering at 3070isdn/3075isdn 7 Registering at Gigaset M101 Data 9 Registering at Gigaset M105 Data 8 Registration not possible 37 Remote adapter 4, 18 de-registering 17, 18 registering 16 Request To Send 13 S Special features Status LED 20 Tab Connection 11 Local adapter 15 Operating mode 12 Remote adapter 18 Tips 24 U USB bus cable and M105 4, 22 W What happens if...