Specifications

PROFINET/Industrial Ethernet
Industrial Ethernet switches
SCALANCE X-100 unmanaged
2/10
Siemens IK PI News · July 2007
2
Technical specifications (continued)
Type SCALANCE X112-2 SCALANCE X116 SCALANCE X124
Data transmission rates
10/100 Mbit/s 10/100 Mbit/s 10/100 Mbit/s
Interfaces
• Communication connection,
electrical
12 x RJ45 sockets
(10/100 Mbit/s; TP)
16 x RJ45 sockets
(10/100 Mbit/s; TP)
24 x RJ45 sockets
(10/100 Mbit/s; TP)
• Communication connection,
optical
2 x BFOC sockets (100 Mbit/s)
• Connection for supply voltage
1 x 4-pole terminal block 1 x 4-pole terminal block 1 x 4-pole terminal block
• Connection for signaling contact
1 x 2-pole terminal block 1 x 2-pole terminal block 1 x 2-pole terminal block
Supply voltage
2 x 24 V DC (18 … 32 V) 2 x 24 V DC (18 … 32 V) 2 x 24 V DC (18 … 32 V)
Current consumption
215 mA 185 mA 200 mA
Power loss at 24 V DC
5.16 W 4.40 W 4.80 W
Network extension parameter /
TP cable length
• 0 … 100 m IE FC Standard Cable GP with
IE FC RJ45 Plug or
through IE FC Outlet RJ45 with
0 … 90 m IE FC Standard Cable +
10 m TP Cord
IE FC Standard Cable GP with
IE FC RJ45 Plug or
through IE FC Outlet RJ45 with
0 … 90 m IE FC Standard Cable +
10 m TP Cord
IE FC Standard Cable GP with
IE FC RJ45 Plug or
through IE FC Outlet RJ45 with
0 … 90 m IE FC Standard Cable +
10 m TP Cord
• 0 … 85 m
IE FC Marine/Trailing/Flexi-
ble/FRNC Cable with IE FC RJ45
Plug or
0 … 75 m IE FC Marine/Trailing
Cable + 10 m TP Cord
IE FC Marine/Trailing/Flexi-
ble/FRNC Cable with IE FC RJ45
Plug or
0 … 75 m IE FC Marine/Trailing
Cable + 10 m TP Cord
IE FC Marine/Trailing/Flexi-
ble/FRNC Cable with IE FC RJ45
Plug or
0 … 75 m IE FC Marine/Trailing
Cable + 10 m TP Cord
• 0 … 55 m
IE TP Torsion Cable with
IE FC RJ45 Plug or
0 … 45 m IE TP Torsion Cable with
IE FC Outlet RJ45 + 10 m TP cord
IE TP Torsion Cable with
IE FC RJ45 Plug or
0 … 45 m IE TP Torsion Cable with
IE FC Outlet RJ45 + 10 m TP cord
IE TP Torsion Cable with
IE FC RJ45 Plug or
0 … 45 m IE TP Torsion Cable with
IE FC Outlet RJ45 + 10 m TP cord
• 0 … 3000 m
Glass fiber-optic cable 62.5/125
µm or 50/125 µm;
1.0 dB/km at 1300 nm;
600 MHz x km
Permissible ambient conditions
• Operating temperature -10 °C … +70 °C -20 °C … +70 °C -20 °C … +70 °C
• Transport/
storage temperature
-40 °C … +80 °C -40 °C … +80 °C -40 °C … +80 °C
• Relative humidity during operation
< 95%, non-condensing < 95%, non-condensing < 95%, non-condensing
Design
• Dimensions (W x H x D) in mm 120 x 125 x 124 120 x 125 x 124 180 x 125 x 124
•Weight
1100 g 1100 g 1500 g
• Assembly
Standard rail, S7-300 rail,
wall mounting
Standard rail, S7-300 rail,
wall mounting
Standard rail, S7-300 rail,
wall mounting
Degree of protection
IP30 IP30 IP30
Approvals
• Radio interference level EN 61000-6-4
(industry, Class A)
EN 61000-6-3
(residential areas, Class B)
EN 61000-6-3
(residential areas, Class B)
• Interference immunity
EN 61000-6-2
(industry, Class A)
EN 61000-6-2
(industry, Class A)
EN 61000-6-2
(industry, Class A)
• CuL listing
UL 60950-1, CSA C22.2
No. 60950-1
UL 60950-1, CSA C22.2
No. 60950-1
UL 60950-1, CSA C22.2
No. 60950-1
•FM
FM 3611 FM 3611 FM 3611
• ATEX Zone 2
EN 60079-15 EN 60079-15 EN 60079-15
•C-Tick
AS/NZS 2064 (Class A) AS/NZS 2064 (Class A) AS/NZS 2064 (Class A)
•CE
EN 61000-6-2,
EN 61000-6-4
EN 61000-6-2,
EN 61000-6-3
EN 61000-6-2,
EN 61000-6-3
Approvals for use
in marine vessels
NN N