Specifications

GEMINI
2
Traffic Outstation Handbook
667/HB/32600/000 Page 154 Issue 11
9.6.5 MOVA Licence Codes
11)
9.6.5
Enter the correct MOVA licence codes, e.g. ‘LIN=1234 5678 and
LIF=123ABC’.
The software licence codes are supplied from Poole and before this can be done the
Serial Number of the Outstation Processor must be obtained. This can be found by
either looking on the card itself or using the Handset code HIC.
Determine whether the site is to be installed with MOVA 4, MOVA 5 or MOVA 6.
MOVA 6 requires firmware PB686 from issue 6 onwards
MOVA 5 requires firmware PB686 to issue 5
NB: This was PB684 on the original Gemini platform)
MOVA 4 requires firmware PB683
MOVA 4 should only be used where compatibility is required with an existing
MOVA 4 site. MOVA 4 is not recommended for new installations.
Poole will then supply two numbers:
1. One represents the code;
2. The other represents the facilities enabled.
The ‘code’ is then entered into the Outstation using the following command:
LIN=xxxx xxxx <CR> where xxxx xxxx represents the unique ‘code number’ for
the site.
The ‘facility’ is then entered into the Outstation using the following command:
LIF=yyyyyyyy <CR> where yyyyyyyy represents the ‘facilities’ available on the
site.
In cases of emergency when it is not possible to contact Poole for licence codes the
following ‘Emergency Code’ can be used
LIN=9999 9999 <CR>
This will enable all facilities for a period of 7 days.
Once a licence number has been issued for the unit, it should be written down on the
MOVA Installation sheet for the unit and kept in the controller cabinet.