Specifications

GEMINI
2
Traffic Outstation Handbook
667/HB/32600/000 Page 156 Issue 11
9.6.7 Download New Site Data (RS, LD, CN and DS)
13)
9.6.7
Download the site data into the MOVA unit from the PC and then
clear the MOVA working data as instructed on the screen.
Caution: If the new site data contains a different number of links, lanes or stages, or
different time-of-day data then MOVA must be re-initialised. Only if the configuration is
the same as the configuration currently running in the MOVA unit (except for minor
changes to timing values), can the new site data be downloaded without initialising the
unit.
Site data is not compatible between different versions of MOVA. The appropriate TRL
version of MOVA Setup will convert between the differing formats, eg. MOVA Setup
M6.0 will convert MOVA 5 data sets to MOVA 6.
MOVA Site Data Loading
New site data can be downloaded into the MOVA unit using the ‘Data Set’ option ‘DS
from the MOVA main menu, followed by the ‘R’ command.
The command is password protected to prevent unauthorised changes to the site data
and can only be attempted locally. The password is case sensitive and is defaulted to
‘AVOMGO’.
Up to four ‘plans’ can be loaded into the MOVA unit’s memory. Normally, only plan 1
will be used. However, it is possible to configure the MOVA unit to switch between the
plans at different times of day. Hence up to four plans, numbered 1 to 4, may have to
be downloaded.
The MOVA site data file name is usually suffixed by the ‘.MDSextension.
When the download of a plan is complete, the MOVA unit enters a dialogue sequence,
typically:-