Specifications
GEMINI
2
Traffic Outstation Handbook
667/HB/32600/000 Page 158 Issue 11
9.6.8 Commissioning Screen (LOOK)
14)
9.6.8
Use the commissioning screen to check for following.
a) MOVA is currently not enabled (MOVA enabled = 0)
b) The Controller is ready* (CRB = 1)
c) The Confirm bits are all set to ‘1’, except for the current stage
which should be set to ‘0’.
Watch the controller perform at least one complete cycle to check
that each stage and phase confirm bit is being activated correctly by
the controller.
* It may be necessary to press the ‘Normal’ button on the controller’s
manual panel before it will activate the ‘Controller Ready Bit’.
15)
9.6.8
Also use the commissioning screen to check the operation of each
detector is correct.
The detector display normally shows ‘0’, turning to a ‘1’ when a
vehicle passes over the loop (or the controller has latched a
pedestrian demand).
Also check that vehicles in adjacent lanes do not activate the loop.
The commissioning screen is used extensively to check the operation of the detectors,
the force bits and the confirm bits. To display the commissioning screen, type ‘LOOK’
from the MOVA Main Menu.
Typical MOVA 6 Comissioning Screen
SIEMENS MOVA COMMISSIONING SCREEN
Detectors: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64
Confirms: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
CRB 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Force Bits: HI/TO 1 2 3 4 5 6 7 8 9 10
MOVA enabled. . 1 Warmup. . . . . 6 Multi stage . . 0 On control. . . 1
Demanded stage . . . 1 Watchdog . . . 9 Error count . . . 0
MOVA COMMISSIONING SCREEN OPTIONS
Press: M to enabled or disable MOVA; C to set MOVA on or off control;
R to refresh the whole screen; X to exit Commissioning Screen;
Z to zero the error count;
1,2,3,... to force a stage (or 0 to cancel current force);
Press a Key:
--- Press a key listed above or Press <Space> for Main Menu ---
The top of the screen shows the live state of all the detector inputs, followed by the
Controller Ready Bit (CRB) and confirm bit inputs from the controller, and the force
bits that the MOVA unit is currently outputting. The ‘MOVA enabled’ and ‘On Control’