Ok accepted by the modem
ATD 9 01202 123456 ask the modem to dial the given number
CONNECT response from modem indicating connection made
Please wait message from MOVA application*
* Press ‘Return’ three times after the ‘connect’ message from the modem to
connect to the MOVA application rather than the RMS OMCU application.
After a short delay, the MOVA unit will then ask for the password to validate remote
access. The password is defaulted to ‘AVOMIN’ although it can be changed.
Once the password has been accepted, the MOVA unit communicates remotely in
exactly the same way as it does locally. The only exception is that downloading plans
and manually forcing stages are prohibited during remote communications.
To end communications with the MOVA unit, select the ‘FI Finish’ option from the
MOVA unit’s main menu. This allows the MOVA unit to tidy-up and close the
communications and hang-up, resulting in ‘NO CARRIER’ being displayed at the
Instation. At this point, press F10 to close the MOVA Communications application.
9.7.2 MOVA Flags (LF and SF)
The MOVA flags can be viewed, and then changed, using the LF (Look at Flags) option
from the main menu:
stage force bits BST
1 2 3 4 5 6 7 8 HI TO Mar Oct MARK1 MARK2 FLAG(29-32)
0 0 0 0 0 0 0 0 0 0 23 15 1234 0 0 0 0 0
error phone watch con- MOVA ready hour stage stage assess error 0=VA
count home dog trol mess flag flow stuck dmnded ment log 1=MOVA
0 0 13 0 0 1 0 0 1 1 0 0
Do you want to Set Flags <S>
Look at Flags <L>
Clear force bits <C>
set Force bits <F>
or Return to MAIN MENU <R> ?
The majority of these flags can be ignored, either because they are more easily viewed
and changed using the commissioning screen for example, or because the flags are set
directly by other options from the main menu.
The Look Flags sub-menu gives five options. In reverse order these are:
Return to MAIN MENU <R>
The fifth and final option is used to return to the main menu.
Set Force bits <F>
Clear force bits <C>
The third and forth options allow force bits to be tested. This option is only provided for
backward compatibility as it is recommended that the commissioning screen be used to
test the force bits.