Reply:
We now need to define the detail of each Reply Word:
For Byte 0:
GRL 0 0=0
GRL 0 1=0
GRL 0 2=0
GRL 0 3=0
GRL 0 4=0
GRL 0 5=0
GRL 0 6=0
GRL 0 7=0
Comment: In this example Reply Byte 0 comes direct from the inputs so set all these
to 0. The initial default for this command is 0 so there is no need to enter
these commands manually. (Only included here for completeness).
For Byte 1:
GRL 1 0=13 ;Handset
GRL 1 1=48 ;DFM
GRL 1 2=14 ;Fault present
GRL 1 3=49 ;HIOCC unit 0
GRL 1 4=56 ;HIOCC unit 7
GRL 1 5=60 ;CQO unit 0
GRL 1 6=75 ;CQO unit 15
GRL 1 7=0
Comment: Reply Byte 1 definitions.
For Bytes 2 to 5:
GRL 2 0=200 ;SCOOT unit 0
GRL 2 4=201
GRL 3 0=202
GRL 3 4=203
GRL 4 0=204
GRL 4 4=205
GRL 5 0=222
GRL 5 4=223 ;SCOOT unit 23
Comment: Reply Bytes 2 to 5 definitions for the SCOOT inputs.
For Byte 6:
GRL 6 0=61 ;Reply byte 6, bit 0 = CQO unit 1
GRL 6 1=74 ;Reply byte 6, bit 1 = CQO unit 14
GRL 6 2=62 ;Reply byte 6, bit 2 = CQO unit 2
GRL 6 3=73 ;Reply byte 6, bit 3 = CQO unit 13
Comment: Reply Bytes 6 definitions for the Occupancy & Queue inputs.