Specifications

GEMINI
2
Traffic Outstation Handbook
667/HB/32600/000 Page 218 Issue 11
Code
Major
Index
Minor
Index
Data
Range
Description
Access
Level
MON
-
SDE
-
SDE/SA monitoring
DATA: (ON/OFF)
RO
MON
-
SEQ
-
Stage Sequence monitoring
DATA: (ON/OFF)
RO
MON
-
STK
-
Controller Stuck monitoring
DATA: (ON/OFF)
RO
MON
-
VMX
-
Vari-Max monitoring
DATA: (ON/OFF)
RO
PDL
-
0 1
-
Display Phase Demands
Latched
MINOR INDEX: 0 Phases A to H
MINOR INDEX: 1 Phases I to P
DATA : 8 BIT BINARY
RO
PDR
-
0 1
-
Display Phase Demand
Revertive
MINOR INDEX 0 Phases A to H
1 Phases I to P
DATA: 8 Bit Binary
RO
PDU
-
0 1
-
Display Phase Demands
Unlatched
MINOR INDEX: 0 Phases A to H
1 Phases I to P
DATA: 8 Bit Binary
RO
SDC
-
**1
A P
-
Display SDE/SA Extension
request for each phase.
MINOR INDEX: PHASE.
DATA: 0 to FFFFH
RO
SMS
-
-
-
Stage Monitoring Status
DATA: Controller timing period.
RO
TIM
-
CLR
-
Clear ALL measured controller
timings. (Enter 1 ; OMCU
responds with 0 when actioned)
WO
TIM
**3
EXL
**2
0 15
-
Display/Reset shortest
measured extension time for
each stage.
MINOR INDEX: STAGE
DATA: Longest Extension in
seconds and tenths of a second.
RW
TIM
**3
EXS
**2
0 15
-
Display/Reset shortest
measured extension time for
each stage
MINOR INDEX: STAGE
DATA: Shortest Extension in
seconds and tenths of a second.
RW