Specifications

GEMINI
2
Traffic Outstation Handbook
667/HB/32600/000 Page 220 Issue 11
SMS: MAX END Stage max time terminating
SMS: AWAIT END Timing monitoring for the stage has completed, waiting for
end of stage
SMS: SHORT MIN Min time was below the defined limit
SMS: SHORT EXT Extension time was below the defined limit
SMS: LONG EXT Extension time was above the defined limit
SMS: LONG MAX The max time was above the defined limit
13.4 INPUT MONITORING COMMAND TABLE
Code
Major
Index
Minor
Index
Data
Range
Description
Access
Level
CCU*
0 1
0 7
-
Display Call/Cancel timers
Major index : 0 = Call time;
1 = Cancel time
Minor index : Call/Cancel unit
DATA: Time (in seconds)
RO
CON
-
0 3
0 65535
Display N+1 COUNTER VALUES
Minor index: N+1 unit
DATA: Count value
RO
COU
-
0 15
0 65535
Display Detector Counter values
Minor index: Counter number
DATA: Count value
RO
DIP
0 3
board
no.
0 5
port no.
00000000 to
11111111
Display digital inputs in binary, for
the selected board and port
number. Not all ports may be
equipped.
Board 0 = 1
st
I/O card
Board 1 = 2
nd
I/O card
Board 2 = 3
rd
I/O card
Board 3 = CPU card
e.g. DIP 0 0 displays board 0 input
port 0, DIP 2 1 displays board 2
input port 1.
RO
LIP
-
0 7
00000000 to
11111111
Display Logical Input Ports
(See Section 13.4.1 for details)
RO