13.8 MAINTENANCE COMMAND TABLE
Code
Major
Index
Minor
Index
Data
Range
Description
Access
Level
BAS
-
-
0 - 2
Handset Display Base:
0 = Binary, 1 = HEX, 2 = Decimal
open
CAL
-
-
0 - 1
Call Instation:
Request local dial-back using
configured telephone numbers.
Write 1, Outstation responds with
0 when actioned
Maint
CBR
-
-
0, 101 -
105
Controller Baud Rate:
Overrides configured setting when
monitoring CX controller:-
0 = 1200 baud (default)
101 = 300 baud
102 = 1200 baud
103 = 2400 baud
104 = 4800 baud
105 = 9600 baud
Maint
EBR
-
-
0 - 31
Engineering Base segment for
RAM display
Segment = EBR value x 10000H
open
EEL
-
-
0 - 255
Examine Enhanced 141 Link to
the ST800/700, values are:-
0 = Not configured
1 = Connecting
2 = Checking ST800/700 (1200
baud)
3 = Link active (19200 baud)
254 = Old ST800/700 firmware
255 = Controller not detected (link
out/power off)
RO
ENR
0 -FFFF
-
ENG
Engineering RAM Display
Starting segment defined by EBR
command
RO