13.20.2 UTMC OTU Control and Reply Bit Allocation Commands
Code
Major
Index
Minor
Index
Data
Range
Description
Access
Level
GSA
-
0 to 23
SCOOT
Loop
0 to 151
Input
Note GSA
references
inputs from
0, ie
GSA 0 = 0
allocates
SCOOT loop
0 to input 1
SCOOT Loop Input Allocation
For each SCOOT loop, enter the
number of the input to which the
SCOOT detector is connected or
255 for unused.
0 to 47 1
st
I/O card inputs
48 to 95 2
nd
I/O card inputs
96 to 143 3
rd
I/O card inputs
144 to 151 CPU card inputs
Default: 255
Maint
LDV
-
-
5 or 8
Load Default Values for OTU
LDV=5 - Load the default values
for a freestanding UTMC OTU
outstation.
LDV=8 - Load the default values
for a semi-integral UTMC OTU
outstation, using a serial link to
communicate with the ST700/800
controller.
See LDV command on page 262
for other values.
Where the outstation is only
required to operate as an OTU it
should be initialised using INI=1
prior to the use of this command.
Maint
GUD
-
0 - 15
U/D
number
0 151
Input
number
U/D Loop Allocation (255)
Unidirectional loop allocation on a
free standing OTU.
For each unidirectional unit (0 to
15), enter the input to which the
normal direction loop connects
(the reverse direction loop is
connected to the next input after
the normal direction loop) or 255
for unused.
0 to 47 1
st
I/O card inputs
48 to 95 2
nd
I/O card inputs
96 to 143 3
rd
I/O card inputs
144 to 151 CPU card inputs
Defaults: 255