Specifications
GEMINI
2
Traffic Outstation Handbook
667/HB/32600/000 Page 317 Issue 11
Code
Major
Index
Minor
Index
Data
Range
Description
Access
Level
GIA
0 – 15
CQO
unit
0
0 – 151
Input
Count, Queue & Occupancy
Input Configuration
Input Allocation:
Configure the input line number
for the count, queue or
occupancy unit.
Note: For N + 1 sites the input
line allocation represents the
kerbside lane loop. The
remaining loops are
connected consecutively to
the next two or three inputs
for two or three lane sites
respectively. If required a
unidirectional function may
be allocated to the last loop
using the GUD command.
Default: 0
Maint
1
0 – 7
Function
Unit Configuration
Configure the function for the unit
as one of the following:
0 = Count/Occupancy/Queue unit
not configured
1 = N count unit (single lane)
2 = 2 lane N + 1 count unit
3 = 3 lane N + 1 count unit
4 = N occupancy unit (single
lane)
5 = 2 lane N + 1 occupancy unit
6 = 3 lane N + 1 occupancy unit
7 = Queue unit
Default: 0
GAQ
-
0 – 15
CQO
unit
0 – 255
Queue
active time
(secs)
Queue Active Time
To specify the time in seconds
that a configured queue unit input
must be active before its output
becomes active.
Default: 0
Maint