Technical data
Error identifier
RS 3 RS 4
Explanation
Table 5-11 continued:
041AH yyyyH Timeout with digital outputs
yyyy = address of the unacknowledged
output flag byte
041BH yyyyH Timeout with IPC flag input
yyyy = address of the unacknowledged
IPC flag byte
041CH yyyyH Timeout with IPC flag output
yyyy = address of the unacknowledged
IPC flag byte
5.5.3
DB2-FE (DB 2 Errors)
Errors in the evaluation of the parameter assignment data block DB 2
for controller structure R64 (controller initialization).
If a DB 2 error occurs, system data words RS 3 and RS 4 contain error
identifiers that define the error in greater detail.
Error identifier
RS 3 RS 4
Explanation
0421H DByyH Data block not loaded
yy = number of the data block that is not
loaded
0422H FByyH Function block not loaded
yy = number of the function block that is not
loaded
0423H FByyH Function block not recognized
yy = number of the unrecognized function
block
0424H FByyH Function block loaded with wrong PG
software
yy =number of the function block
0425H DByyH Wrong controller data block length
yy = number of the data block
0426H — There is not enough memory space in the
DB-RAM to shift the controller DBs from the
user EPROM to the DB-RAM
Table 5-12 IDs for DB 2 errors
5
Errors during RESTART
CPU 928B Programming Guide
C79000-B8576-C898-01 5 - 35