Technical data

The range of values and meaning of the parameters is as follows:
Parameters Permissible value range
Data block type (source and destination) 1 = DB
2 = DX
Data block number (source and
destination)
3...255
No. of the 1st data word (source and
destination)
0...4090
Number of data words 1...4091
Data field in the flag area
If you set up the data field in the flag area, you must take into account
the following assignment of data field words to flag bytes. "x" is the
parameter "no. of the 1st data field word", that you must store in
ACCU-1-L when OB 182 is called.
Bit no. 15 8 7 0
1st data field word Flag byte x Flag byte x+1
2nd data field word Flag byte x+2 Flag byte x+3
3rd data field word Flag byte x+4 Flag byte x+5
4th data field word Flag byte x+6 Flag byte x+7
5th data field word Flag byte x+8 Flag byte x+9
2. Accus
2a) ACCU-2-L
Der ACCU-2-L enghält Angaben zum verwendeten Datenfeld. Er
muß folgenden Aufbau haben:
Parameters in ACCU-2-L
Address area type,
permitted values: 1 = DB data block
2 = DX data block
3 = F flag area
4 = S flag area
Data block no.,
permitted values : 3 to 255 (in the case of address area type "1"
or "2" only; irrelevant in the case of address
area type "3" or "4")
15 8 7 0Bit no.
Address area type Data block no.
OB 182: Copying a Data Area
CPU 928B Programming Guide
6 - 66 C79000-B8576-C898-01