Technical data

6.30 OB 230 to 237: Functions for Standard Function Blocks
The special function organization blocks OB 230 to OB 237 are
reserved for data handling functions and can only be called in the
standard function blocks FB 120 to FB 127.
Data handling blocks
These standard function blocks, the data handling blocks known
simply as "handling blocks", control the data exchange via the page
area in the single and multiprocessor modes. They are used when data
or parameters and control information are transferred to or from the
communications processors (CPs).
Assignment aid
You can use the table below to find out which handling blocks call the
special function organization blocks OB 230 to OB 237.
Standard
function block
Special function
Organization block
Handling
block
FB 120
FB 121
FB 122
FB 123
FB 124
FB 125
FB 126
FB 127
SF-OB 230
SF-OB 231
SF-OB 232
SF-OB 233
SF-OB 234
SF-OB 235
SF-OB 236
SF-OB 237
SEND
RECEIVE
FETCH
CONTROL
RESET
SYNCHRON
SEND ALL
RECEIVE ALL
Using the handling blocks
The use of the handling blocks, that can be ordered as a software
product on diskette, is described in the manual "S5 135U
programmable controller, handling blocks for the R processor and
CPU 928/928B" /5/ in Chapter 13).
OB 230 to 237: Functions for Standard Function Blocks
CPU 928B Programming Guide
6 - 100 C79000-B8576-C898-01