Technical data

RS 6
CYCLE and Submodule/MPL IDs
Address: EA06H
The IDs correspond to the control bits in lines 3 and 4 of the ISTACK.
High byte: CYCLE IDs
Bit no.
Assignment
15
RUN
14
not used
13
EIN-PROZ
12
BARB
11
OB1-GEL
10
FB0-GEL
9
OB-PROZA
8
OB-WECKA
Low byte: Submodule/MPL IDs
7
32KW-RAM
6
16KW-RAM
5
8KW-RAM
4
EPROM
3
KM-AUS
2
KM-EIN
1
DIG-EIN
0
DIG-AUS
Table 8-6 Assignment of RS 6 (Cycle and submodule/MPL IDs)
User Memory Organization in the CPU 928B
CPU 928B Programming Guide
8 - 24 C79000-B8576-C898-01