Instruction manual

Bulletin 700-HXM
Plug-in Timing Relays
9-110
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P
Counter Function
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Input Mode
Up Down Up/Down B.C
Output
mode
N
Reset
9999
0
-999
Output
SV
F
Reset
9999
0
-999
Output
SV
C
Reset
9999
0
-999
Output
SV
tt t
ttt-a
ttt-a
K
Reset
9999
0
-999
Output
SV
t-a t t-a
t-a t
t-a t
Note: t-a: Less than the output time
t: Output time
Totalizing counter continues to count the present value, regardless
of whether an reset input (by the reset key) has been made to
reset the PV.
When totalizing count value has reset, the PV is reset at the same
time.
The totalizing count range is 0…99999999. If the totalizing count
exceeds 99999999, the count returns to 0. If the count drops
below 0, it becomes 99999999.
Reset
Totalizing Count Reset
(Reset Key)
PV
Totalizing Count Value
Totalizing Counter Operation
If there is a power failure during output ON, output will turn ON again when the power supply has recovered. For one-shot output, an output
will be made again for the duration of the output time setting once the power supply has resumed. Output timing restarted during one-shot
outputs is ignored.
Counter Function
Input/Output Mode Settings