Overview/Product Selection
Table of Contents
Accessories . . . . . . . 9-121
Specifications . . . . . 9-125
Approximate
Dimensions . . . . . . . 9-127
Standards
UL 508
CSA C22.2, No. 14
EN/IEC 60947-1, -5-1
Certifications
cULus Listed (File No. E14840,
Guide NKCR/NKCR7)
ABS Certified
Description
The Bulletin 700-P family of relays has four types of contact cartridges to meet your specific switching requirements. Different cartridges can
be combined into one relay to yield a custom-tailored application solution. Time delay, latching attachments, overlapping, and logic reed
contacts are available.
Bulletin 700-P relays use standard (10 A) contact cartridges with a double-break and bifurcated design. Bifurcation provides excellent
contact reliability and low-contact bounce, while the double-break contact design reduces the possibility of contacts welding and enhances
the relay’s ability to break DC circuits. These relays are supplied with a max. of 12 contacts (max. 8 N.C.).
Bulletin 700-PK master control relays contain (20 A) master contact cartridges with large single-contact pads on each side of the spanner for
twice the current rating to control heavy loads and for master control of a system. The Bulletin 700-PK relay also has the same doublebreak
design as the 700-P relay. These relays are supplied with a max. of 12 contacts (max. 8 N.C.). Time delay and latching attachments are
available.
Bulletin 700-P and -PK relays combine the advantages of convertible contacts with Direct Drive, a construction designed to maintain non-
overlap operation between N.O. and N.C. contacts (within published ratings).
Bulletin 700-PH relays contain (35 A) tandem contact cartridges. A jumper kit (Cat No. 700-CPH) allows two (20 A) master contact
cartrridges to be connected in parallel. A maximum of six poles are supplied, up to four of which can be normally closed. Time delay and
latch attachments are available.
700-P
Bulletin 700-P and 700-PK — Direct Drive™ Convertible
Contact Cartridge Relays
NEMA and IEC ratings
600V maximum AC/DC
Accessories for field installation: Adder Decks, time delay, latching,
surge suppressors, mounting strip
Contact Ratings: (10 A) 700-CP1, (20 A) 700-CPM, (35 A) 700-CPH,
(Low Power) 700-CPR
For machine tool and other heavy-duty applications
Can accommodate ring tongue terminals
Integral DIN Rail adapter on AC relays
Finger-safe protection standard
Electrically Held Relays
Bulletin 700-P Standard Contact Cartridge
1
AC-Operated Relays
Contacts
Contact Arrangement
and Markings
Open Type
Relay Rail
Mount
®
N.O. N.C. Cat. No.
2
—
4-Pole
Relay
700-P200⊗
4—
700-P400⊗
⊗
6
—
8-Pole
Relay
700-P600⊗
⊗
8—
700-P800
⊗
10
—
12-Pole
Relay
700-P1000⊗
⊗
12 —
700-P1200
⊗
⊗AC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-P200⊗
becomes Cat. No. 700-P200A48. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
Hz 24 48 110 110-115 115-120 120 127 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600
50 B24 B48
A1
B11
— — B27 — B22 B2 — — B3 B41 B44 — B50 —
60
A24 A48 — —
A1
B11
— A20 A22 A2 A27 A35 — — — A4 — A6
Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz. Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.
‡ Location of contacts in 2-pole relays. § Location of contacts in 6-pole relays: 4-pole relay plus the two contacts indicated.
♣ Location of contacts in 10-pole relays: 8-pole relay plus the two contacts indicated.
1 Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts.
Overlap contacts: T
o order a relay containing one pair: Use Cat. No. 700-PZ110. To order a relay containing two pairs: Use Cat. No. 700-PZ2220. N.O.
contact closes before N.C. contact opens. AC Ratings: NEMA A600, DC Ratings: P161.
® See Accessories on page 9-123 for NEMA Type 1, Type 4/4X, and Type 7/9 enclosures available for field installation.