Instruction manual
Bulletin 700-P
Heavy-Duty Industrial Relays
9-116
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P
Product Selection
0
1
2
3
4
5
6
7
8
9
10
11
12
13
DC-Operated Relays
Contacts
Contact Arrangement
and Markings
Open Type
Relay Rail
Mount
®
Open Type
DIN Rail Mount
®
N.O. N.C. Cat. No. Cat. No.
2
—
4-Pole
Relay
700DC-P200⊗ 700DC-P200D⊗
4—
700DC-P400⊗
⊗
700DC-P400D⊗
6
—
8-Pole
Relay
700DC-P600⊗ 700DC-P600D⊗
8—
700DC-P800⊗
⊗
700DC-P800D⊗
10
—
12-Pole
Relay
700DC-P1000⊗ 700DC-P1000D⊗
12 —
700DC-P1200⊗ 700DC-P1200D⊗
⊗DC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-
P200
⊗
becomes Cat. No. 700DC-P200Z48. For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley
distributor.
6 12 18 24 32 48 64 72 90 115-125 230-250 500-550 575-600
Z06 Z12 Z18
Z24
Z32 Z48 Z64 Z72 Z90 Z1 Z2 Z5 Z6
Electrically Held Relays
Bulletin 700-PK Master Contact Cartridges
1
AC-Operated Relays
Contacts
Contact Arrangement
and Markings
Open Type
Relay Rail Mount
Type 1®
General Purpose
N.O. N.C.
Cat. No. Cat. No.
2
—
4-Pole
Relay
700-PK200⊗
⊗
700-PK201⊗
4—
700-PK400
⊗
700-PK401⊗
6
—
8-Pole
Relay
700-PK600⊗
⊗
700-PK601⊗
8—
700-PK800
⊗
700-PK801⊗
10
—
12-Pole
Relay
700-PK1000⊗ 700-PK1001⊗
12 —
700-PK1200⊗
⊗
700-PK1201⊗
⊗AC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No.700-
PK200
⊗
becomes Cat. No.700-PK200A48 for 48V 60 Hz. For other coil voltages, consult your local Rockwell Automation sales office or
Allen-Bradley distributor.
Hz 24 48 110 110-115 115-120 120 127 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600
50 B24 B48
A1
B11
— — B27 — B22 B2 — — B3 B41 B44 — B50 —
60
A24 A48 — —
A1
B11
— A20 A22 A2 A27 A35 — — — A4 — A6
Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz.
Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.
1 Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts.
Overlap contacts: T
o order a relay containing one pair: Use Cat. No. 700-PZ110. To order a relay containing two pairs: Use Cat. No. 700-PZ2220. N.O.
contact closes before N.C. contact opens. AC Ratings: NEMA A600, DC Ratings: P161.
‡ Location of contacts in 2-pole relays.
§ Location of contacts in 6-pole relays: 4-pole relay plus the two contacts indicated.
♣ Location of contacts in 10-pole relays: 8-pole relay plus the two contacts indicated.
® See Accessories on page 9-123 for NEMA Type 1, Type 4/4X, and Type 7/9 enclosures available for field installation.