Instruction manual
Bulletin 700-P
Heavy-Duty Industrial Relays
9-119
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P
Product Selection
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Time Delay Relays — Open Type With Pneumatic Time-Delay Attachment
Factory-Assembled Bulletin 700-PT and PKT Timing Relays
− Timing Range — 0.1…60 s
− 0, 2, or 4 instantaneous contacts
− Two timed contacts — both ON Delay or both OFF Delay
− Convertible from ON Delay to OFF Delay and vice versa
− Standard contact cartridges rated NEMA A600 (AC) and P600 (DC)
− Master contact cartridges rated 2X NEMA A600 (AC) and 2X P600 (DC)
Bulletin 700-P Standard Contact Cartridge1
AC-Operated Relays DC-Operated Relays
Contacts
Contact Arrangement and Markings
Open Type
Relay Rail
Mount
Contact Arrangement and Markings
Open Type
Relay Rail
Mount
Open Type
DIN Rail Mount
N.O. N.C.
Cat. No. Cat. No. Cat. No.
0 — Relay with only time delay contacts
700-PPT
⊗
Relay with only time delay contacts
700DC-PPT⊗ 700DC-PPTD⊗
2—
700-PT200
⊗
700DC-PT200⊗ 700DC-PT200D⊗
4—
700-PT400
⊗
700DC-PT400⊗ 700DC-PT400D⊗
Bulletin 700-PK Master Contact Cartridges1
AC-Operated Relays DC-Operated Relays
Contacts
Contact Arrangement
Open Type
Relay Rail
Mount
Contact Arrangement
Open Type
Relay Rail
Mount
Open Type
DIN Rail Mount
N.O. N.C.
Cat. No. Cat. No. Cat. No.
0 — Relay with only time delay contacts
700-PPKT⊗
Relay with only time delay contacts
700DC-PPKT⊗ 700DC-PPKTD⊗
2—
700-PKT200⊗
700DC-
PKT200⊗
700DC-
PKT200D⊗
4—
700-PKT400⊗
700DC-
PKT400⊗
700DC-
PKT400D⊗
⊗AC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700-
PKT200⊗ becomes Cat. No. 700-PKT200A48 for 48V 60 Hz. For other coil voltages, consult your local Rockwell Automation sales office or
Allen-Bradley distributor.
Hz 24 48 110 110-115 115-120 120 127 200-208 220-230 230-240 277 347 380 415 440-480 460-480 500 575-600
50 B24 B48
A1
B11
— — B27 — B22 B2 — — B3 B41 B44 — B50 —
60
A24 A48 — —
A1
B11
— A20 A22 A2 A27 A35 — — — A4 — A6
Optimized for 115…120V, 60 Hz. Operates satisfactorily at 110V, 50 Hz.
Optimized for 110…115V, 50 Hz. Operates satisfactorily at 120V, 60 Hz.
⊗DC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a voltage suffix code from the table below to complete the Cat. No. Example: Cat. No. 700DC-
PKT200
⊗
becomes Cat. No. 700DC-PKT200Z12 for 12V DC. For other coil voltages, consult your local Rockwell Automation sales office or
Allen-Bradley distributor.
6 12 18 24 32 48 64 72 90 115-125 230-250 500-550 575-600
Z06 Z12 Z18
Z24
Z32 Z48 Z64 Z72 Z90 Z1 Z2 Z5 Z6
1 Normally closed contacts: The normally open contacts can easily be changed to normally closed in the field. Relays can be supplied with N.C. contacts.
Overlap contacts: N.O. contact closes befor
e N.C. contact opens. To order a relay containing one pair: Use Cat. No. 700-PTZ110. To order a relay containing
two pairs: Use Cat. No. 700-PTZ2220. AC Ratings: NEMA A600, DC Ratings: P161.
‡ Location of contacts in 2-pole relays.
♣ Timer has 1 N.O. and 1 N.C. convertible cartridge in addition to the instantaneous cartridges on the relay. Timer is supplied as On-Delay
. Convertible to Off-
Delay in the field.
® The timer has 1 N.O. and 1 N.C convertible master cartridge in addition to the instantaneous master cartridges on the relay. Timer is supplied as On-Delay. It is
convertible to Off-Delay in the field.