Features
Mechanically linked contacts meet IEC 947-5-1-L
2…12 poles – all mechanically linked
Red cover for easy identification of safety circuits
Tamper resistant cover helps prevent changes which could jeopardize
safety
IEC mechanically linked contacts symbol displayed on front
Visual indication of contact state
Ideal for use in safety circuits
Table of Contents
Specifications.............. 9-129
Approximate
Dimensions...................
9-130
Certifications
cULus Listed (File No. E14840,
Guide NKCR/NKCR7)
CE Certified
ABS Certified
Standards Compliance
UL 508
CSA C22.2 No. 14
Product Selection
Bulletin 700S-P (10 A) Safety Control Relays — AC and DC Coil Voltages
Contacts
AC Coils 24V DC Coils
Open Type Panel Mount Relay Rail
Mount
Open Type Panel Mount Relay Rail
Mount
Open Type DIN Rail
Mount
Cat. No.1 Cat. No.1 Cat. No.1
N.O. N.C.
31
700S-P310
700S-DCP310Z24 700S-DCP310DZ24
22
700S-P220
700S-DCP220Z24 700S-DCP220DZ24
71
700S-P710
700S-DCP710Z24 700S-DCP710DZ24
62
700S-P620
700S-DCP620Z24 700S-DCP620DZ24
53
700S-P530
700S-DCP530Z24 700S-DCP530DZ24
44
700S-P440
700S-DCP440Z24 700S-DCP440DZ24
35
700S-P350
700S-DCP350Z24 700S-DCP350DZ24
10 2
700S-P1020
700S-DCP1020Z24 700S-DCP1020DZ24
AC Coil Voltage Code
The Cat. No. as listed is incomplete. Select a coil voltage code from the table below to complete the Cat. No.
Example: Cat. No. 700S-P310 becomes Cat. No. 700S-P310A1 for a 120V AC coil.
[V] 24 115-120 230-240 460-480
60 Hz A24
A1
A2 A4
1 For other coil voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
IEC 947-5-1 Annex L has 2 requirements for a relay to meet for mechanically linked contacts:
1.) If a N.O. contact welds, all the N.C. contacts will remain open and meet a 2500V impulse test.
2.) If a N.C. contact welds, all the N.O. contacts will remain open and meet a 2500V impulse test.
Bul. Nos. 700S-P and 700S-DCP relays meet these requirements including the 2500V impulse test.
The relays shown on this page are shipped from the factory with the Bul. 700-CPS safety cartridge installed and cannot be converted to N.O.
or N.C. in the Field.
Bulletin 700S-PK (20 A) Safety Control Relays
Contacts
Coil Voltage
Cat. No.N.O. N.C.
7
1 110V AC
700S-PK710A1
6 2 110V AC
700S-PK620A1
5
3 110V AC
700S-PK530A1
4 4 110V AC
700S-PK440A1
3
5 110V AC
700S-PK350A1
10 2 110V AC
700S-PK1020A1
3 1 110V AC
700S-PK310A1
7 1 24V DC
700S-DCPK710Z24
6 2 24V DC
700S-DCPK620Z24
5 3 24V DC
700S-DCPK530Z24
4 4 24V DC
700S-DCPK440Z24
3 5 24V DC
700S-DCPK350Z24
10 2 24V DC
700S-DCPK1020Z24
3 1 24V DC
700S-DCPK310Z24