9-133
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P
Accessories
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Description Cat. No.
Relay Rail
Simplifies panel layout. These indexed strips are easily cut to
the required length and bolted, riveted, or spot-welded in
place. Relays are installed adjacent to one another on the
mounting strip with the captive mounting screws provided.
Rows of relays on Relay Rail form their own wiring trough.
Can be used with the following relays: 700P, 700-PK, 700PH,
700S-P, 700N, 700-R, 700-RTC
Relays per strip
4
700-MP4
8
700-MP8
12
700-MP12
Universal Mounting Strip 16
700-MP16
DIN Rail Adapter
700-DRA
Cat. No. 700-DRA
Front Deck
Front decks can be attached to Bulletin 700 4-pole relays.
Provides up to 4 additional convertible poles – without
changing the mounting area.
Front Deck without Contact
Cartridges
700-NA00
Cat. No. 700-NA00
Standard Contact Cartridges
Available for adding to both rear deck and front deck.
Rear Deck Contact Cartridge
1
700-C1
Front Deck Contact Cartridge
1
700-C2
Gold-Plated Contact Cartridges
May be used in low power circuits to improve reliability. Good
for long term storage, because gold resists corrosion.
Rear Deck Contact Cartridge
1
700-C1X
Front Deck Contact Cartridge
1
700-C2X
Logic Reed Cartridges
Cartridges are hermetically sealed contact for low energy
switching.
Rear Deck Contact Cartridge
(150V AC, 150 mA, 8VA Max.)
(30V DC, 60 mA Max.)
1
700-C1R
Bifurcated Contact Cartridges
Cartridges are less apt to open because of vibration and
shock.
Rear Deck Contact Cartridge
1
700-C1B
Front Deck Contact Cartridge
1
700-C2B
Overlap Contact Cartridges
Cartridges are available in pairs. The N.O. contact closes
before the N.C. contact opens.
300V AC max.
125V DC max.
Rear Deck Contact Cartridge
(1 pair in a package)
1
700-C11Z
Cat. No. 700-C11Z
Front Deck Contact Cartridge
(1 pair in a package)
1
700-C22Z
Timing Unit Replacement (Bifurcated) Contact Cartridge for
Bulletin 700-NT relay
Timing Unit Deck Contact Cartridge
1
X-457011
Jumpers (Not applicable for Bulletin 700-PH or -PK relays) –
For connection between a middle pole and an outer pole on
the left or right side of the relay.
Jumper for middle pole to outer poles
700-N3
Cat. No. 700-N4,-N3 Jumper for middle poles
700-N4
Gold-Plated Contact Timing Unit Replacement Cartridge
1
40163-447-03
Surge Suppressors (RC Circuit) — Surge suppressors reduce
the high transient voltages generated when the coil circuit is
opened. These suppressors can be used with Bulletin 700-P, -
PH, -PK, and -N relays, and other electromechanical devices.
They contain a resistor and capacitor. Maximum ratings: 150V,
AC or DC, 35 VA. Cat. No. 700-N5 requires 1 in. additional
depth of enclosure.
For mounting behind relay
(1 in. additional depth needed)
700-N5
Cat. No. 700-N5 Cat. No. 700-N24 For mounting on coil terminal
700-N24
Check Out Tool
Mechanically maintains the Bulletin 700-N relay in operated
position.
Check Out Tool for Bulletin 700-N AC
relay
700-N21
Cat. No. 700-N21
1 All contact cartridges are convertible (N.O. or N.C.).