Instruction manual
Bulletin 700-CF
IEC Industrial Control Relays
9-147
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Product Overview/Product Selection
Bulletin 700-CF — Control Relay
IEC industrial relays
Mechanically linked contact performance per IEC 60947-5-1
Gold plated, bifurcated version for low level switching applications
Master control relay version rated 15 A (AC-15)
Solid-state and pneumatic timing modules
4-…10 Poles
Standards Compliance
Certifications
4-Pole AC Coil Voltage (Ratings for 700-CF Only)
AC-12 AC-15
Connection
Diagrams
Contacts
Standard
Contacts
Cat. No.
Gold Plated
Bifurcated
Contacts
Cat. No.
1
Master
Contacts
Cat. No.
1
I
th
[A]
I
e
[A]
40 °C 60 °C 24/48V 120V 240V 400V 500V 600V 690V N.O. N.C.
20 20 10 10 10 6 2.5 1 1
22
700-CF220⊗ 700-CFB220⊗
700-CFM220⊗
⊗
31
700-CF310⊗ 700-CFB310⊗
700-CFM310
⊗
40
700-CF400⊗ 700-CFB400⊗
700-CFM400
⊗
11
12
21
22
31
32
41
42
04
700-CF040
⊗
700-CFB040
⊗
—
For spring clamp terminals, insert R after 700-C. Example: Cat. No. 700-CRF220D.
⊗ AC Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 700-CF220⊗
becomes Cat. No. 700-CF220D for 120V, 60 Hz
[V] 122432364248100
100
...
110 110 120 127 200
200
...
220 208
208
...
240
220
...
230 230
230
...
240 240 277 347 380
380
...
400 400
400
...
415 440 480 500 550 600
50 Hz R K V W X Y KP — D P S KG L — — F — VA T — — — N — G B — M C —
60 Hz Q J — V — X — KP — D — — KG H L — — — A T I E — — — N B — — C
50/60 Hz — KJ — — — KY KP — KD — — KG KL — — KL KF — KA — — — — KN — KB — — — —
4-Pole DC Coil Voltage (Ratings for 700-CF Only)
AC-12 AC-15
Connection
Diagrams
Contacts
Standard
Contacts
Cat. No.‡
Gold Plated
Bifurcated
Contacts
Cat. No.
1
Master
Contacts
Cat. No.
1
I
th
[A]
I
e
[A]
40 °C 60 °C 24/48V 120V 240V 400V 500V 600V 690V N.O. N.C.
20 20 10 10 10 6 2.5 1 1
22
700-CF220⊗ 700-CFB220⊗
700-CFM220⊗
⊗
31
700-CF310⊗ 700-CFB310⊗
700-CFM310
⊗
40
700-CF400⊗ 700-CFB400⊗
700-CFM400
⊗
‡ For spring clamp terminals, insert R after 700-C. Example: Cat. No. 700-CRF220ZJ.
⊗ DC Coil Voltage Code§
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. example: Cat. No. 700-CF220⊗
becomes Cat. No. 700-CF220ZJ for 24V DC
[V] 9 12243648
48...
72 60 64 72 80 110
110...
125 115 125 220
220...
250 230 250
Standard ZR ZQ ZJ ZW ZY — ZZ ZB ZG ZE ZD — ZP ZS ZA — ZF ZT
Standard diode — — DJ — — — — — — — — — — — — — — —
Electronic with diode — EQ EJ — — EY — — — — — ED — — — EA — —
§ When ordering DJ coil with built-in surge suppression, the DJ is not polarity sensitive. Drop out time: 14…20 ms.
UL 508
CSA C22.2 No. 14
EN/IEC 60947-1, -5-1
Meets the material restrictions
for European Directive
2002/95/EC - EU-RoHS
Table of Contents
Product Selection...... this page
Accessories.................. 9-150
Specifications.............. 9-154
Approximate
Dimensions................... 9-156
cULus Listed (File No. E14840, Guide NKCR/NKCR7)
CE Marked
CCC Certified
1 Ratings for Bulletin 700-CFB and 700-CFM are on page 9-159
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P