Instruction manual

Bulletin 700-CF
IEC Industrial Control Relays
9-151
Accessories
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Control Modules
Description
Connection
Diagrams Reset Time
Repeat
Accuracy Delay For Use With Cat. No.
Pneumatic Timing Modules1 ON-Delay
Pneumatic timing element contacts
switch after the delay time. The contacts
on the main control relay continue to
operate without delay.
25…90 ms
for AC Coils
47…85 ms
for DC coils
+/-10%
0.3…30 s
700-CF all
1
100-FPTA30
1.8…180 s
100-FPTA180
Pneumatic Timing Modules OFF-Delay
Pneumatic timing element contacts
switch after the delay time. The contacts
on the main control relay continue to
operate without delay.
0.3…30 s
100-FPTB30
1.8…180 s
100-FPTB180
Electronic Timing Modules — On-Delay
Delay of the control relay coil assembly.
The control relay is energized at the end
of the delay time.
100 ms +/-1%
0.1…3 s 700-CF
110…240V AC
110…250V DC
coils
100-ETA3
1…30 s
100-ETA30
10…180 s
100-ETA180
0.1…3 s
700-CF
24…48V DC
coils
100-ETAZJ3
1…30 s
100-ETAZJ30
10…180 s 100-ETAZJ180
Electronic Timing Modules — Off-Delay
Delay of the control relay coil assembly.
After interruption of the control signal, the
control relay is deenergized at the end of
the delay time.
100 ms +/-1%
0.3…3 s
700-CF
110…240V AC
coils
100-ETB3
1…30 s
100-ETB30
10…180 s
100-ETB180
0.3…3 s
700-CF
24V AC
coils
100-ETBKJ3
1…30 s
100-ETBKJ30
Cat. No. 100-ETB30 10…180 s
100-ETBKJ180
1 On-Delay modules cannot be used with side-mounted auxiliary contacts on DC coil relays.
Description
Connection
Diagrams For Use With Cat. No.
Mechanical Latch
Following relay latching, the relay coil is immediately de-energized (off)
by the N.C. auxiliary contact (65-66).
Electrical or manual release
1 N.O. + 1 N.C. auxiliary contacts
700-CF with AC
coils
100-FL11
Cat. No. 100-FL
Description
Connection
Diagrams
For Use
With
Cat. No.
Surge Suppressors
For limitation of coil
switching transients.
Plug-in, coil mounted
RC Module
AC Operating
Mechanism
24…48V
50/60 Hz
700-CF
with AC
coils
100-FSC48
110…280V
50/60 Hz
100-FSC280
380…480V
50/60 Hz
100-FSC480
Varistor Module
AC/DC Operating
Mechanism
12…55V AC/
12…77V DC
700-CF all
100-FSV55
56…136V AC/
78…180V DC
100-FSV136
137…277V AC/
181…350V DC
100-FSV277
278…575V AC
100-FSV575
Diode Module
DC Operating
Mechanism
Dropout Time
70…95 ms
12…250V DC
700-CF
with DC
coils
100-FSD250
For spring clamp terminals, insert CR after 100-. Example: Cat. No. 100-CRFSC48.
Coil Voltage Code
The cat. no. as listed is incomplete. Select a coil voltage code from the table below to complete the cat. no. Example: Cat. No. 100-FL11
becomes Cat. No. 100-FL11J.
[V] 24 48 100 110 120 230...240 240 277 380...400 400...415 440 480
50 Hz
K Y KP D VA T N G B
60 Hz
J D A T N B
For special voltages, consult your local Rockwell Automation sales office or Allen-Bradley distributor.
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P