Instruction manual

Bulletin 700-CF, 700-CFB, 700-CFM
IEC Industrial Control Relays
9-154
Specifications
0
1
2
3
4
5
6
7
8
9
10
11
12
13
General
Main Relay
Cat. Nos.
700-CF, 700S-
CF
Front Mounted
Standard
Auxiliary
Contacts
Main Relay
Cat. No.
700-CFB, 700S-
CFB
Master Relay
Cat. No.
700-CFM
Front Mounted
Bifurcated
Auxiliary
Contacts
Side-mounted
Auxiliary
Contacts
Contact Ratings — NEMA A600, P600 A600, Q600 A600, Q600 2 x A600, P600 A600, Q600 A600, Q600
Min. Contact Rating 17V, 10 mA 17V, 5 mA 8V, 5 mA 5V, 3 mA 17V, 10 mA
Contact Ratings — IEC AC-15
(solenoids, contactors) at rated
voltage
IEC 60947-5-1
24V 10 A 6 A 3 A 15 A 3 A 6 A
48V 10 A 6 A 3 A 15 A 3 A 6 A
120V 10 A 6 A 3 A 15 A 3 A 6 A
240V 10 A 5 A 3 A 15 A 3 A 5 A
400V 6 A 3 A 2 A 7.5 A 2 A 3 A
480V/500V 2.5 A 1.6 A 1.2 A 5 A 1.2 A 1.6 A
600V 1 A 1 A 0.7 A 2 A 0.7 A 1 A
690V 1 A 1 A 0.7 A 2 A 0.7 A 1 A
AC-12 (Control
of resistive
loads)
IEC 60947-5-1
40 °C
I
th
20 A
10 A 10 A 20 A 10 A 10 A
230V 8 kW
400V 14 kW
690V 24 kW
60 °C
I
th
20 A
6 A 6 A 20 A 6 A 6 A
230V 8 kW
400V 14 kW
690V 24 kW
DC-12 Switching DC Loads
L/R < 1ms, Resistive Loads
IEC 60947-5-1
24V 15 A 10 A 6 A 20 A 6 A 6 A
48V 10 A 9 A 3.2 A 20 A 3.2 A 3.2 A
110V 6 A 3.5 A 1 A 8 A 1 A 1 A
220V 1 A 0.7 A 0.5 A 1.5 A 0.5 A 0.5 A
440V 0.4 A 0.2 A 0.2 A 0.4 A 0.2 A 0.2 A
DC-13 IEC 60947-5-1, Solenoids
and contactors
24V 5 A 5 A2.5 A5 A2.5 A5 A
48V 3 A 3 A1.5 A3 A1.5 A2.5 A
110V 1.2 A 1.2 A 0.6 A 1.2 A 0.6 A 0.68 A
220V 0.6 A 0.6 A 0.3 A 0.6 A 0.3 A 0.32 A
440V 0.3 A 0.15 A 0.15 A 0.3 A 0.15 A 0.15 A
Cat. No.
700-CF
Aux./Pneu
matic
Timer
Contact
(Front-
mounted)
Mechanical Life [Mil] 15 5
Electrical Life
AC-15
(240V, 3 A)
[Mil] 1.5 1.5
Weight AC Coil [g] 390
Terminal Cross-Sections
Terminal Type
Terminal Size per IEC60 947-1 2 x A4 2 x A4
Solid/
Stranded
1
Conductor
[mm
2
] 1.5…6 0.5…2.5
§
2
Conductor
[mm
2
] 1.5…6 0.75…2.5
Max. Wire Size per UL/CSA [AWG] 16…10 18…14
Tightening Torque [lb·in] 13.3…22 8.9…13.3
Tightening Torque [N·m] 1.5…2.5 1…1.5
§ For 16 or more strands, end ferrule is required.
DC Switching Ratings for 700-CF Main Poles in Series (Resistive Load at
60 °C)
1 pole 2 poles 3 poles
24/48V 25/20 A 25 A 25 A
125V 6 A 25 A 25 A
220V 1.5 A 8 A 25 A
440V 0.4 A 1 A 3 A
Location of welded N.O.
contacts
State of N.C. Contacts if N.O. contact welds
Main Front aux. Side aux.
Main Open Open Open
1
Mechanically Linked
Contacts
Front aux. Open Open
1 Side mounted auxiliary contacts provide “mirror contact” performance with main poles only.
Defined in IEC 60947-5-1 annex L. Mechanically linked is a relationship between contacts of opposite types (i.e., N.O. and N.C.).
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P