Instruction manual

Bulletin 700S-CF
IEC Industrial Control Relays
9-161
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P
Typical Application
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Safety Relay Circuit With 5 Safety Outputs
Use for E-stop control. E-stop will work properly if any one fault occurs (a fault could be one welded contact or one undesired open
connection such as a loose wire).
High output switching capability and long contact life.
Circuit complies with EN 954 categories 1, 2, 3, 4.
Helps prevent restart of the 5 safety outputs if there is a single fault anywhere in the system.
Use (3) 700S-CF relays and this diagram to construct the circuit
Basic Circuit
(1) Output Circuit (3 Relays, 9 Terminal Blocks)
(5) Output Circuit (3 Relays, 17 Terminal Blocks)
Basic Circuit
(1) Output Circuit (3 Relays, 9 Terminal Blocks)
Push To Stop
Pull To Reset
Start
LOAD 1
LOAD 2
LOAD 3
LOAD 4
LOAD 5
Included in factory
wired units
1 Numbers shown are the line numbers where the contacts for this relay appear.
Contact your local Rockwell Automation sales office or Allen-Bradley distributor for availability.