Instruction manual
Bulletin 700-SA
Solid-State Relays
9-172
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P
Specifications
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Control/Input Ratings
Cat. No.
Rated Control
Voltage
Max. Operating
Control Voltage Range
Max. Reverse
Control Voltage Impedance
Control Voltage Levels
Pick-up Voltage Drop-out Voltage
700-SAZY5Z25
5…24V DC
4…32V DC -32V DC 15 mA max.
1
4V DC max. 1V DC min.
700-SANY3Z25 4…30V DC -30V DC
1.5 kΩ (+20% -10%)
Load/Output Ratings
Cat. No. Rated Load Voltage
Maximum Load
Voltage Range
Continuous Load Current (Resistive) [A]
Max. Inrush Current‡Min.
Max
700-SAZY5Z25 100…240V AC 75…264V AC 0.1 5.0
80 A, @ 50/60 Hz
for 1 cycle
700-SANY3Z25 5…110V DC 3…125V DC 0.1 3.0 12 A (10 ms)
Characteristics
Description Cat. No. 700-SAZY5Z25 Cat. No. 700-SANY3Z25
Load Switching Method/Device Triac Transistor
Pick-up Time
1/2 cycle of load power source cycle time§ + 1 ms
max.
0.5 ms max.
Dr
op-out Time
1/2 cycle of load power source cycle time§ + 1 ms
max.
2.5 ms max.
Output ON V
oltage Drop 1.6V (RMS) max. 1.5V max.
Output Leakage Current 5 mA max. (at 100V AC); 10 mA max. (at 200V AC) 5 mA max. (at 125V DC)
Output V
DRM
V
CEO
(V)
600 150
Output di/dt (A/uS) 50 —
Output dv/dt (V/uS) 500 —
Output
I
2
t (A
2
S)
41.6 —
Output Tj (ºC) Max. 125 150
Insulation Resistance
100 MΩ min. (at 500V DC)
Dielectric Strength 1500V AC, 50/60 Hz for 1 min
Vibration Resistance (Max.) 10…55 Hz, 1.5 mm double amplitude (10 G)
Shock Resistance (max.) 1000 m/s
2
(100 G)
Ambient Temperature
Operating –30…80 °C (–22…176 °F) with no icing or condensation
Storage –30…100 °C (–22…212 °F) with no icing or condensation
Ambient Humidity 45…85% (no condensation)
Standards Compliance UL 508, CSA C22.2 No. 14, EN 60947-1, -4-3
Certifications cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, VDE Certified
Weight Approx. 70 g
1 With constant current input system. SSR input impedance varies with a change in input (control) voltage.
Refer to the following graph “Load Current Vs. Ambient Temperature Characteristics” for additional load current details.
‡ If the SSR operation is continuous ON/OFF, this value should be reduced by 50%. Refer to “Inrush Current Resistivity” graph below
.
§ 60 Hz full cycle time = 16.6 ms, 50 Hz full cycle time = 20 ms.
Load Current vs. Ambient Temperature Characteristics
Inrush Current Resistivity♣
700-SA
Ambient Temperature [° C]
Load Current [A]
700-SA
Inrush Current [A. Peak]
Energizing Time [ms]
700-SAZY5Z25
700-SANY3Z25
0
1
2
3
4
5
-30
-20
0
20
40
60
80
100
700-SANY3Z25
700-SAZY5Z25
80
70
60
50
40
30
20
10
0
10
30
50
100
200
500
1000
5000
♣ Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max.
repeatability once every 5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will
damage the SSR.