Specifications
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Output Module, Continued
Characteristics
Description Cat. No. 700-SKOZ2Z25 Cat. No. 700-SKON2Z25 Cat. No. 700-SKOC2Z25 Cat. No. 700-SKOC1Z25
Load Switching Method/Device Triac Transistor
Pick-up Time
1/2 cycle of load power source cycle time
1
+ 1 ms max.
1 ms max.
Drop-out Time 1/2 of load power source cycle time
1 + 1 ms max. 2 ms max.
Response Frequency 20 Hz 100 kHz
Output ON Voltage Drop 1.6V max. 2.5V max.
Leakage Current 1.5 mA max. 1 mA max.
Output V
DRM
, V
CEO
(V)
600 (ref.value) 600 (ref.value) 80 (ref.value) 400 (ref.value)
Output di/dt (A/uS) 30 30 — —
Output dv/dt (V/uS) 300 300 — —
Output
I
2
t (A
2
S)
10.4 10.4 — —
Output Tj (°C) Max. 125 125 150 150
Insulation Resistance
100 MΩ min. between input and output
Dielectric Strength 4000V AC, 50/60 Hz for 1 min between input and output
Vibration Resistance (Max.) 10…55 Hz, 1.5 mm double amplitude (10 G)
Shock Resistance (Max.) 1000 m/s
2
(100 G)
Ambient Temperature
Operating –30…+80 °C (–22…+176 °F) with no icing or condensation
Storage –30…+100 °C (–22…+212 °F) with no icing or condensation
Standards Compliance UL 508, CSA C22.2 No. 14, EN/IEC 60950
Certifications cURus Recognized (File No. E96956, Guide NMFT2/NMFT8), CE Marked, TÜV Certified
Ambient Humidity Operating 45…85% (no condensation)
Weight Approx. 18 g
1 60 Hz cycle time = 16.6 ms, 50 Hz cycle time = 20 ms.
Load Current vs. Ambient Temperature Characteristics
2
1.5
1
0.5
-20
0
20
40
60
80
100
For 2 A Versions
Ambient Temperature [° C]
Ambient Temperature [° C]
Maximum Load Current (A)
2
1.5
1
0.5
-20
0
20
40
60
80
100
Maximum Load Current (A)
Inrush Current Resistivity
10
9
8
7
6
5
4
3
2
1
0
10
9
8
7
6
5
4
3
2
1
0
10
20
30
Energizing Time (ms)
Energizing Time (ms)
Energizing Time (ms)
Inrush Current (A)
Inrush Current (A)
Inrush Current (A)
10
30
50
100
200
500
1000
5000
10
30
50
100
300
500
1000
2000
10
30
50
100
300
500
1000
2000
700-SKOZ/SKON
700-SKOC2 700-SKOZ/SKOC1
Inrush current resistivity is the ability of an SSR to withstand a large surge current for a short period of time. Surges are considered non-repetitive (max.
repeatability once every 2…5 seconds). Keep the inrush current to half the rated value if it occurs repetitively. Exceeding the non-repetitive inrush current will
damage the SSR.