Instruction manual
Bulletin 700-SK
Solid-State Relays
9-194
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P
Approximate Dimensions
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Note: The input module ( Bul. 700-SKI) and output module (Bul. 700-SKO) are compatible with the Cat. No. 700-HN121 socket.
(+)
(–)
Load
Input
13 max.
28 max.
57.5
9.6
3
4
1
2
20
3
4
1
5
(–) (+)
0.5
5.2
17.4
4.7
4.75
4.75
0.5
10
4
15
Terminal Arrangement/
Internal Connections
(Bottom View)
29 max.
Application Considerations of Bulletin 700-SK
Connection
For DC load switching, Bulletin 700-SK SSR will operate properly if the load is connected to either the positive or negative SSR load terminal.
The load can be connected to either positive or negative output terminals of the SSR.
Protective Element (to extend SSR life)
Since the SSR does not incorporate a surge absorption component, be sure to connect a surge absorption component when using the SSR
to control an inductive load.
For additional details applying solid-state relays, refer to pub. 700-AT001A*, Solid-State Relay Application Guide.
All units are in millimeters unless otherwise indicated. To convert to inches multiply by 0.0394. Dimensions are not to be used for
manufacturing purposes.