Instruction manual

Bulletin 900-TC8 Controller Models
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Product Selection
9-196
Bulletin 900-TC
Digital Temperature Controller
Bulletin
No. DIN Size
Sensor Input
Type
Power
Supply
Voltage
Max No. of
Auxiliary
Outputs
Supported
®
Control Output 1 Type
Control Output
2 Type
Supports
Heater
Burnout
(Open) and
Heater Short-
Circuit Alarm
Controller Cat. No.
900-TC8
1
1/8 DIN
48 mm
(W) x 96
mm (H) x
78 mm
(D)
Thermocouple
or R
TD
100…
240V AC
3
Relay
—No
900-TC8RGTZ25
Yes
(1-Phase)
900-TC8RGTH1Z25
Voltage (for
driving SSR)
No
900-TC8RVGTZ25
Yes
(3-Phase)
900-TC8RGTH3Z25
Voltage (for driving SSR)
—No
900-TC8VGTZ25
Yes
(1-Phase)
900-TC8VGTH1Z25
TRIAC
No
900-TC8VYGTZ25
Voltage (for
driving SSR)
No
900-TC8VVGTZ25
Yes
(3-Phase)
900-TC8VGTH3Z25
0...20 or 4...20 mA Analog
Output
—No
900-TC8ACGTZ25
TRIAC
No
900-TC8ACYGTZ25
Voltage (for
driving SSR)
No
900-TC8ACVGTZ25
Thermocouple
or RTD
24V AC/DC 3
Relay
—No
900-TC8RGTU25
Yes
(1-Phase)
900-TC8RGTH1U25
Voltage (for driving SSR)
—No
900-TC8VGTU25
Yes
(1-Phase)
900-TC8VGTH1U25
0...20 or 4...20 mA Analog
Output
—No
900-TC8ACGTU25
Analog
Current &
Voltage 0...20
and 4...20 mA
0...5, 1...5,
and 0...10V
DC
100…
240V AC
3
Relay
Yes
(1-Phase)
900-TC8RABH1Z25
Relay No
900-TC8RABZ25
Voltage (for driving SSR)
Yes
(1-Phase)
900-TC8VABH1Z25
Voltage (for driving SSR) No
900-TC8VABZ25
Voltage (for driving SSR)
TRIAC
No
900-TC8VYABZ25
0...20 or 4...20 mA Analog
Output
—No
900-TC8ACABZ25
1 A current transformer (CT) is not provided with the unit.
When the heating and cooling function or the heater burnout alarm is used, one of the relay alarm outputs will be disabled for each function used.
For AC voltage operation only
® Typically used for alarms or cooling output in a heat/cool application
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P