Instruction manual
Accessories
Current Transformer (Use with Bulletins 900-TC8 and 900-TC16 Only for Heater Burnout or Heater Short)
For Use With Bulletin No. Hole Diameter1 Cat. No.
900-TC8, 900-TC16
5.8
900-CT1
12.0
900-CT2
1 The hole diameter is the only functional difference between the Cat. No. 900-CT1 and the Cat. No. 900-CT2. Current output to controller is the same.
Interface Converter (RS-232/USB to RS-485) Model
Converts personal computer RS-232 or USB (Ser. B or later) communications to RS-485. Use for interface with a single Bulletin 900-TC8, or
Bulletin 900-TC16 with a Cat. No. 900-TCxxCOM unit installed or a single Cat. No. 900-TC32C_ designated controller. Also allows interface
to up to 31 controllers connected on a RS-485 link/network. See 900-CONV for additional details.
Bulletin No. Size Power Supply Voltage Cat. No.
900-CONV 30 mm (W) x 80 mm (H) x 78 mm (D)
100…240V AC
900-CONVZ25
24V AC/DC
900-CONVU25
RS-232 Interface Cable
Accessory Cat. No.
RS-232 cable with 9-pin female D shell and 3 flying leads (3 m)
900-CP1X
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Product Selection/ Accessories
9-198
Bulletin 900-TC
Digital Temperature Controller
Option Units (Bulletins 900-TC8 and 900-TC16 — Only One Option Unit per Controller)
The unit provides communications or event input functionality.
Bulletin No. Name Function Cat. No.
900-TC8
Communications Unit
RS-232C communications‡
900-TC8232(B)
RS-485 communications
900-TC8COM(B)
Event Input Unit
Event input
900-TC8EIM
900-TC16
Communications and 1-Phase Heater
Burnout Unit and Heater Short
RS-485 communications with single-phase heater burnout (open) and heater
short-circuit failure detection
900-TC16NCOM(B)♠§
Event Input Unit with 1-Phase Heater
Bur
nout and Heater Short
Event Input with single-phase heater burnout (open) and heater short-circuit
failure detection
900-TC16NEIM(B)♠
Event Input Unit
Event Input
900-TC16NACEIM(B)♠
Communications Unit RS-485 communications
900-
TC16NACCOM
(B)♠§
Communications and 3-Phase Heater
Bur
nout and Heater Short Unit
RS-485 communications with 3-phase heater burnout (open) and heater short-
circuit failure detection
900-
TC16NCOMP3
(B)♠§
Communications and Second Voltage
(SSR) Output Unit
RS-485 communications and a second voltage (SSR) output
900-
TC16NCOMV2
(B)♠§
1-Phase Heater Burnout and second
voltage (SSR) output
1-Phase Heater bur
nout (open) and heater short-circuit failure detection with a
second control voltage (SSR) output
900-TC16P1V2(B)♠
‡ Enables direct RS-232 connection to personal computer using 900Builder™ Lite software. A Cat. No. 900-CP1X cable or equivalent is also r
equired.
Provides two event inputs. Allows selecting up to 4 different pre-configured set points, controller Run/Stop or Auto/Manual mode, fr
om 2 external inputs.
Heater burnout is not available for 0...20 or 4…20 mA analog output style 900-TC16 controllers such as the 900-TC16AC.
To obtain 57.6 k baud rate, Series B communication units must be used with any 900-TC8 controller catalog number from the Product Selection table on the
pr
evious page.
♠ Series B option units must be used with Series B 900-TC16 controllers. Series A option units cannot be used with Series B controllers and vice versa.
§ Series B provides 57.6 K baud rate.
Allows connection between a 900-TC8 with a 900-TC8232 option unit and a PC using 900Builder Lite software or PC with software and a
900-CONV RS232-to-RS485 converter.
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P