Instruction manual
SUB
SUB
No. 1 Display (Green, Red, Amber)
Displays the process value or parameter type.
No. 2 Display (Green)
Displays the set point, manipulated vairable, or
configured value (setup) of the parameter.
Up Key
Each press of this key increases values displayed
on the No. 2 display. Holding down this key
continuously increases values.
Down Key
Each press of this key decreases values displayed on
the No. 2 display. Holding down this key continuously
decreases values.
Function Group + Mode Keys
This key combination sets the Bulletin 900-TC16
to the protect function group.
Mode Key
Press this key to select parameters within each
function group.
4-pin Serial Port For USB Cable (900-CPOEM 1)
Function Group Selection Key
Press this key to select the setup function
group. This setup function group is selected in order
operation function group adjustment function group
communications setting function group.
Operation Indicators
1. SUB 1 - Lights when auxiliary 1 output is ON
SUB 2 - Lights when auxiliary 2 output is ON
2. HA (red heater burnout alarm display) - Lights when a heater
burnout is detected. The heater burnout alarm remains ON by
setting the heater burnout latch. To reset, turn the power
supply OFF and then ON or set the heater burnout alarm
value to 0.0 A.
3. OUT1, OUT2 (amber control output 1, control output 2) - lights
when control output 1 and or control output 2 are ON.
4. STOP (amber stop) - lights when control of the Bulletin
900-TC16 has stopped. During control, this indicator lights
when an event or run/stop function has become stopped.
Otherwise, this indicator is out.
5. CMW (amber communications writing control) - Lights when
communicationswriting is enabled and is out when it is disabled.
6. MANU (Manual Mode) - Lights when the controller mode is in
manual
7. (Key) - Lights when the settings change protection in ON
Keys disabled.
Temperature Unit
Temperature units are displayed when
the display unit parameter is configured for
temperature. Indication is determined by the
currently selected temperature unit parameter
set value. When this parameter is set to °C, c is
displayed, and when set to °F, f is displayed.
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Specifications
9-200
Bulletin 900-TC
Digital Temperature Controller
Specifications §
General Functions
Bulletin 900-TC8
2(
#/
MV
SV
PV
57$
57$
5612176
/#07
%/9176
57$
*#
No. 3 Display (Amber)
Displays manipulated variable soak time
remaining or multi SP.
4-pin Serial Port for
USB Cable
(900-CPOEM 1)
Operation Indicators
1. SUB 1 - Lights when auxiliary 1 output is ON
SUB 2 - Lights when auxiliary 2 output is ON
SUB 3 - Lights when auxiliary 3 output is ON
2. HA (red heater burnout alarm display) - Lights when a heater
burnout is detected. The heater burnout alarm remains ON by
setting the heater burnout latch. To reset, turn the power supply
OFF and then ON or set the heater burnout alarm value to 0.0 A.
3. OUT1, OUT2 (amber control output 1, control output 2) - lights
when control output 1 and or control output 2 are ON.
4. STOP (amber stop) - lights when control of the Bulletin 900-TC8
has stopped. During control, this indicator lights when an event or
run/stop function has become stopped. Otherwise, this indicator is out.
5. CMW (amber communications writing control) - Lights when
communications writing is enabled and is out when it is disabled.
6. MANU (Manual Mode) - Lights when the controller mode is in manual
7. (Key) - Lights when the settings change protection in ON
Keys disabled.
Temperature Unit
Temperature units are displayed when
the display unit parameter is configured for
temperature. Indication is determined by the
currently selected temperature unit parameter
set value. When this parameter is set to °C, c
is displayed, and when set to °F, f is displayed.
No. 1 Display (Green, Red, Amber)
Displays the process value or parameter type.
No. 2 Display (Green)
Displays the set point, manipulated vairable, or
configured value (setup) of the parameter.
Up Key
Each press of this key increases values displayed on
the No. 2 display. Holding down this key continuously
increases values.
Down Key
Each press of this key decreases values displayed on
the No. 2 display. Holding down this key continuously
decreases values.
Function Group + Mode Keys
This key combination sets the Bulletin 900-TC8
to the protect function group.
Mode Key
Press this key to select parameters within each function group.
Function Group Selection Key
Press this key to select the setup function
group. This setup function group is selected in
order operation function group adjustment
function group communications setting
function group.
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P