Instruction manual

Bulletin No.
700-HA 700-HB 700-HD 700-HF
Type General-Purpose Relay General-Purpose Relay General-Purpose Relay General-Purpose Relay
Features
Pin-style terminals
Standard ON/OFF flag
indicator
Electrical schematic on face
Clear cover for visual
inspection
Optional Push-to-test and
manual override
Optional LED
Blade-style quick connect
terminals
Standard ON/OFF flag
indicator
Electrical schematic on face
Clear cover for visual
inspection
Optional push-to-test and
manual override
Optional LED
Flange-mounted
Blade-style quick connection
terminals
Clear cover for visual
inspection
Square-base
Plug-in quick connect solder
terminals
Optional push-to-test and LED
Contact Ratings
Contact Form DPDT, 3PDT DPDT, 3PDT DPDT, 3PDT DPDT, 3PDT, 4PDT
Contact Type Single Single Single Single
Contact Material AgNi, AgNi + Gold AgCdO AgCdO AgCdO
Max. operating
current under
resistive load
700-HA: 10 A
-HAX: 6 A
15 A 15 A 10 A
Min. permissible
load
700-HA 10V 5 mA
700-HAB 5V 5 mA
700-HAX 6V 1mA
10V 10 mA 10V 10 mA 5V 100 mA
Coil Ratings
Coil Voltage
AC: 6, 12, 24, 48, 110, 120, 208,
230, 240, 277V
DC: 6, 12, 24, 36, 48, 60, 80,
110, 125, 140, 220V
AC: 6, 12, 24, 120, 240V
DC: 6, 12, 24, 48, 110V
AC: 6V, 12V, 24V, 120V, 208V,
240V
DC: 6V, 12V, 24V, 48V, 110V
AC: 6V, 12V, 24V, 120V, 240V
DC: 6V, 12V, 24V, 48V, 110V
Permissible Coil
Voltage Variation
80…110% of Nominal Voltage at
50 Hz
80…110% of Nominal Voltage at
60 Hz
80…110% of Nominal Voltage at
DC
80…110% of Nominal Voltage at
50 Hz
80…110% of Nominal Voltage at
60 Hz
80…110% of Nominal V
oltage at
DC
80…110% of Nominal Voltage at
50 Hz
80…110% of Nominal Voltage at
60 Hz
80…110% of Nominal Voltage at
DC
85…110% of Nominal
Voltage at 50 Hz
85…110% of Nominal
Voltage at 60 Hz
80…110% of Nominal
Voltage at DC
Electrical Ratings
Dielectric
Withstand Voltage
Pole-to-pole: 2000V
Contact-to-coil: 2000V
Contact-to-frame: 2000V
Pole-to-pole: 2500V
Contact-to-coil: 4000V
Contact-to-frame: 2500V
Pole-to-pole: 2500V
Contact-to-coil: 4000V
Contact-to-frame: 2500V
Pole-to-pole: 1500V AC
Contact-to-coil: 1500V AC
Contact-to-frame: 1500V AC
Electric Service
Life (cycles)
100 000 minimum 100 000 minimum 100 000 minimum
200 000 minimum, 500 000
minimum (DPDT)
Reference
Certifications CE, cULus, cURus, CSA, Lloyds CE, cULus, cURus, CSA, Lloyds CE, UR, CSA, Lloyds CE, UR, CSA
Socket Cat. No(s).
700-HN100, 700-HN101, 700-
HN125, 700-HN126, 700-HN204,
700-HN205
700-HN153,
700-HN154
700-HN116, 700-HN138, 700-
HN139
Page Number page 9-9 page 9-20 page 9-26 page 9-29
Bulletin 700
Relays, Timers & Temperature Controllers
9-3
Product Overview
0
1
2
3
4
5
6
7
8
9
10
11
12
13
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P