Instruction manual

Bulletin 700
Relays, Timers, & Temperature Controllers
9-4
Product Overview
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Bulletin No.
700-HC 700-HK 700-HL 700-HP
Type Interposing/Isolation Relay Interposing/Isolation Relay Interposing/Isolation Relay Interposing/Isolation Relay
Features
Blade-style terminals
Standard ON/OFF flag
indicator
Electrical schematic on face
Clear cover for visual
inspection
Optional push-to-test and
manual override
Optional LED
Optional pilot light
Retainer clip (comes with
socket)
Low switching capacity
Push-to-test & manual override
Ideal for PLC Interfaces
Built-in Coil Surge Protection
Fully Assembled Relay/Sockets
Standard LED
Relay or Solid-state Output
Optional: Leakage Current
Suppression Solution
PCB “Pin Style” mounting
5 mm pin spacing
Contact Ratings
Contact Form DPDT, 4PDT SPDT, DPDT
SPDT
1 N.O. (SSR)
DPDT
Contact Type Single Single Single Single
Contact Material AgNi, AgNi + Gold AgNi, AgNi + Gold AgSnO AgNi, AgNi + Gold
Max. operating
current under
resistive load
10 A (DPDT)
7 A (4PDT)
8 A (DPDT), 16 A (SPDT)
6 A (SPDT), 2 A (SSR DC output),
1 A (SSR AC output)
8 A
Min. permissible
load
10V, 10 mA (Gold), 5V, 10 mA or
25V, 2 mA (Silver)
5V 60 mA (Silver), 5V 10 mA
(Gold)
12V 6 mA (72 mW) Silver
8V, 2.5 mA (20 mW) Gold
5V 5 mA (50 mW) Gold,
5V 5 mA (300 mW) Silver
Coil Ratings
Coil Voltage
AC: 6, 12, 24, 120, 240V
DC: 6, 12, 24, 48, 110V
AC: 6, 12, 24, 120, 240V
DC: 6, 12, 24, 48, 110V
AC: 12, 24, 48, 110, 120, 230,
240V
DC: 12, 24, 48, 125, 230, 240V
AC: 6, 12, 24, 120, 240V
DC: 6, 12, 24, 48, 110V
Permissible Coil
Voltage Variation
80…110% of Nominal Voltage at
50 Hz
80…110% of Nominal Voltage at
60 Hz
80…110% of Nominal Voltage at
DC
80…110% of Nominal Voltage at
50 Hz
80…110% of Nominal V
oltage at
60 Hz
73…110% of Nominal Voltage at
DC
85…110% of Nominal Voltage at
50 Hz
85…110% of Nominal Voltage at
60 Hz
80…110% of Nominal Voltage at
DC
80…110% of Nominal Voltage at
50 Hz
80…110% of Nominal Voltage at
60 Hz
73…150% of Nominal Voltage at
DC
Electrical Ratings
Dielectric
Withstand Voltage
Pole-to-pole: 1000V
Contact-to-coil: 2000V
Contact-to-frame: 2000V
Pole-to-pole: 1500V AC
Contact-to-coil: 1500V AC
Contact-to-frame: 1500V AC
Pole-to-pole: 1000V AC
Contact-to-coil: 4000V
Contact-to-frame: 1500V
Pole-to-pole: 2000V
Contact-to-coil: 5000V
Electric Service
Life (cycles)
100 000 minimum 100 000 minimum 100 000 minimum 100 000 minimum
Reference
Certifications CE, cULus, cURus, CSA, Lloyds CE, UL, UR, CSA CE, cURus, cULus, ABS CE, cULus, cURus, CSA, Lloyds
Socket Type
700-HN103, 700-HN128, 700-
HN104
700-HN121, -HN221
700-HN122, -HN222
700-HN223, -HN224
700-HN123, -HN230
Page Number page 9-34 page 9-39 page 9-45 page 9-58
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P