Instruction manual
Bulletin 700-FS
DIN Rail Mounted Timing Relays
9-67
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P
Product Selection
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Multi-Function
(This device allows the flexibility of selecting one of 8 single timing functions.)
Operating Mode Contact Output Timing Range Input Voltage Cat. No.
Multi-function timing relays
8 Single-functions:
A, B, C, D, E, F, I, and L
ON and OFF function additional
(for installation and maintenance)
note: See connection diagrams for further
description.
(SPDT) 1 C/O
0.05 s…60 hr
12V DC
700-FSM3UZ12
(SPDT) 1 C/O
24…48V DC
24…240V AC
50/60 Hz
700-FSM3UU23
(DPDT) 2 C/O 12V DC 700-FSM4UZ12
(DPDT) 2 C/O
24…48V DC
24…240V AC
50/60 Hz
700-FSM4UU23
Note: Information for hazardous location versions of this product (-EX) is available on the Industrial Controls Catalog website: www.ab.com/catalogs.
Multi-Function With Hazardous Location Certification ♣
(This device allows the flexibility of selecting one of 8 single timing functions.)
Operating Mode Contact Output Timing Range Input Voltage Cat. No.
M Multi-function timing relays
8 Single-functions:
A, B, C, D, E, F, I, and L
ON and OFF function additional
(for installation and maintenance)
Note: See connection diagrams for further
description.
(SPDT) 1 C/O
0.05 s…60 h
1
24…48V DC
24…240V AC
50/60 Hz
700-FSM3UU23-EX
(DPDT) 2 C/O
700-FSM4UU23-EX
♣
Temp. Code
T4A 2A
32VDC
MAX.
II 3 G, EEx nL IIC T4 DEMKO 04 ATEX 0404974X
2A 32VDC MAX. Ta ≤ 70 °C
Ind. Cont. Eq. for Hazardous Location Listed 87SL
Class 1, Div. 2, Groups A,B,C,D Class 1, Zn 2, Group IIC
Mounting: Product shall be installed in an enclosure constructed in accordance with the requirements of EN50021.
Single Function (With 2PDT 2 C/O contacts)
Operating Mode Contact Output Timing Range Input Voltage Cat. No.
On-delay (DPDT) 2 C/O
0.05 s…60 hr‡
12V DC
700-FSA4UZ12
On-delay (DPDT) 2 C/O
24…48V DC
24…240V AC, 50/60 Hz
700-FSA4UU23
Off-delay (DPDT) 2 C/O 12V DC
700-FSB4UZ12
Off-delay (DPDT) 2 C/O
24…48V DC
24…240V AC, 50/60 Hz
700-FSB4UU23
‡ The time range of "0.05 s…60 hr" is selectable in 12 smaller ranges plus an ON and OFF function for maintenance needs.
Note: Information for hazar
dous location versions of this product (-EX) is available on the Industrial Controls Catalog website: www.ab.com/catalogs.
Single Function With Hazardous Location Certification ♣ (With SPDT 1 C/O contacts)
Operating Mode Contact Output Timing Range Input Voltage Cat. No.
One Shot / Watch Dog
(Pulse Controlled)
(SPDT) 1 C/O
0.05 s…1 s 24…48V DC
24…240V AC
50/60 Hz
700-FSK3AU23-EX
0.5 s…10 s
700-FSK3CU23-EX