Instruction manual
Bulletin 700-HNK
Plug-in Timing Relays
9-82
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P
Timing Ranges
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Operating Modes
Operating Mode Setting Factory-set
On-delay
Yes
One Shot
No
Repeat Cycle Off-start
No
Repeat Cycle On-start
No
Note: The right two DIP switch pins are used to select the operating modes.
Time Ranges
Cat. No. Time Range Time Setting Range Setting Factory-Set
700-HNK41AZ12
700-HNK41AZ24
700-HNK41AA24
700-HNK42AZ12
700-HNK42AZ24
700-HNK42AA24
1 s 0.1…1 s
Yes
10 s 1…10 s
No
1 min 0.1 s…1 min
No
10 min 1…10 min
No
700-HNK41BZ12
700-HNK41BZ24
700-HNK41BA24
700-HNK42BZ12
700-HNK42BZ24
700-HNK42BA24
1 min 0.1…1 min
Yes
10 min 1…10 min
No
1 hr 0.1…1 hr
No
10 hr 1…10 hr
No
Note: The left two DIP switch pins are used to select the time ranges.