Instruction manual

Bulletin 700-HR
Plug-in Timing Relays
9-89
Specifications
0
1
2
3
4
5
6
7
8
9
10
11
12
13
700-HR, -
HRS, -HRV
700-HRP 700-HRC 700-HRM 700-HRF 700-HRY 700-HRQ
700-HRT
(Transistor
Outputs)
Electrical Ratings
Pilot Duty Rating NEMA B300
Thermal Current (
I
th
)
5 A
100 mA @ 30V
DC max.
120V AC 30 A
Make 240V AC 15 A
120V AC 3 A
Break 240V AC 1.5 A
Hp at 120V
1/6 Hp (0.12
kW)
1/4 Hp (0.18 kW) 1/6 Hp (0.12 kW)
1/4 Hp (0.18
kW)
1/6 Hp (0.12
kW)
Hp at 240V 1/3 Hp (0.25 kW)
Resistive Load 5 A at 250V AC/30V DC
Inductive Load AC-15 @ 250V AC, 3 A/DC-13 @ 30V DC, 0.5 A
Accuracy of Operating Time ±0.2 % FS max. (±0.2 % ±10 ms max. in a range of 1.2 s)
Setting Error ±5 % FS ±50 ms (The value is ±5 % FS +100 ms to -0 ms max. when the C or D mode signal of the 700-HRVs are OFF.)
Influence of Voltage ±0.2 % FS max. (±0.2 % ±10 ms max. in a range of 1.2 s)
Influence of Temperature ±1 % FS max. (±1 % ±10 ms max. in a range of 1.2 s)
Permissible Leakage Current
Power Consumption -HR52, -HRS -HRV -HRP, -HRC -HRM -HRF -HRY -HRQ -HRT
240V AC, Output ON 2.1 VA 2.5 VA 2.0 VA 2.1 VA 10 VA 12 VA 0.4 VA
240V AC, Output OFF 1.3 VA 1.8 VA 2.0 VA 1.3 VA 10 VA 12 VA 0.4 VA
24V DC, Output ON 0.8 W 0.9 W 0.9 W 0.8 W 1.0 W 0.2 W 0.3 W
24V DC, Output OFF 0.2 W 0.3 W 0.9 W 0.2 W 1.0 W 0.2 W 0.2 W
Design Specifications
Dielectric Strength
2000V AC (1000V AC for 700-HRT), 50/60 Hz for 1 min (contact to frame)
2000V AC (1000V AC for 700-HRT), 50/60 Hz for 1 min (between control output terminals and operating circuit)
2000V AC, 50/60 Hz for 1 min (pole-to-pole)
1000V AC, 50/60 Hz for 1 min (between contacts not located next to each other)
2000V AC, 50/60 Hz for 1 min (contact to coil)
Mechanical
Vibration Resistance Malfunction: 10…55 Hz with 0.5 mm double amplitude each in three directions for ten minutes each
Shock Resistance Malfunction: 100 m/s
2
(10 G)
98 m/s
2
(10 G)
294 m/s
2
(10 G)
98 m/s
2
(10 G)
100 m/s
2
(10 G)
Environmental
Noise Immunity ±1.5 kV for ±600V DC ±400V for 12V DC
±1kV for
48V DC
±1.5 kV for
±600V DC
Static Immunity Malfunction: 8 kV
Ambient Temperature
Operating: -10…55 °C (with no icing)
Storage: -25…65 °C (with no icing)
Ambient Humidity Operating: 35…85 %
Construction
Life Rxpectancy
(Min. Operations)
Mechanical:20 000 000. (under no load at 1800 operations/h)
Electrical: 100 000 (5 A at 250V AC, resistive load at 1800 operations/h)
Mech: 10
7
Electrical: 10
4
EMC
(EMI) EN50081-2
Emission Enclosure:EN55011 Group 1 class A
Emission AC Mains: EN55011 Group 1 class A
(EMS) EN50082-2
Immunity ESD:EN61000-4-2:4 kV contact discharge (level 2)
8 kV air discharge (level 3)
Immunity RF-interference from AM Radio Waves: ENV50140:10 V/m (80 MHz…1 GHz) (level 3)
Immunity RF-interference from Pulse-modulated Radio Waves:ENV50204:10 V/m (900 ±5 MHz) (level 3)
Immunity Conducted Disturbance:ENV50141:10 V (0.15…80 MHz) (level 3)
Immunity Burst:EN61000-4-4:2 kV power-line (level 3)
Immunity Surge:EN61000-4-52 kV I/O signal-line (level 4)
1 kV line to line
2 kV line to ground (level 3)
Degree of Protection IP40 (panel surface)
Weight Approx. 90 g
Certifications CSA Certified (File No. 70751), UL Recognized (File No. E14843 Guide No. NRNT2), CE Marked, C-Tick Marked
Standards UL 508, CSA C22.2 No. 14, EN 61812-1, EN 61000-6-2, -6-4
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P