Instruction manual
Bulletin 700-HX
Plug-in Timing Relays
9-98
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P
Specifications
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Electrical Ratings
Pilot Duty Rating NEMA B300
Rated supply voltage
100 to 240V AC, 24V AC/12 to 24V DC (50/60Hz) (permissible ripple: 20%(p-p)
max.)
Operating voltage range 85…110% of rated supply voltage
Power consumption
100…240V AC 4.3VA
24V AC/12…24V DC 3.4VA/1.7 W
Inrush Current
100…240V AC 3 A
24V AC/12…24V DC 5 A
120V AC 30 A
Make 240V AC 15 A
120V AC 3 A
Break 240V AC 1.5 A
Hp at 120V AC 1/4 Hp
Hp at 240V AC 1/3 Hp
Mechanical
Mounting Method Flush mounting, surface mounting, DIN mounting
Display
Seven-segment, negative transmissive LCD; Present value (red, 12 mm high
characters); Set value (green, 6 mm high characters)
Digits Four digits
Timer
Time ranges
0.000…9.999 s, 0.00…99.99 s, 0.0…999.9 s, 0…9999 s, 0 min 00 s…99 min 59
s, 0.0…999.9 min, 0 hr 00 min…99 hr 59 min, 0.0 hr…999.9 hr, 0 hr…9999 hr
Timer modes Elapsed time (Up), remaining time (Down), selectable
Output modes A, A-1, A-2, A-3, B, B-1, D, E, F, Z, S, tOFF, tON, tOFF-1, or tON-1
Inputs
Input signals Start, reset
Input method No-voltage input via:NPN transistor or switching of contact
Start, reset, gate Minimum input signal width: 1 or 20 ms (selectable)
Power reset Minimum power-opening time: 0.5 s (Except for A-3, B-1, and F mode)
Control output
SPDT contact output: 5 A at 250V AC, resistive load (cosine=1)
Minimum applied load: 10 mA at 5 V DC (failure level: P, reference value)
External Power Supply No
Key Protect Yes
Memory Backup
EEP-ROM (overwritten 100 000 times min), which can store data for 10 years
min.
Accuracy of Operating Time and Setting Error
1
Power-ON start: +-0.01% +-50 ms max.
* to be rated against set value
Signal start: +- 0.005% +-30 ms max.
* to be rated against set value
Signal start at transistor output model: +- 0.005% +-3 ms max.
If the set value is within the sensor waiting time
(250 ms max.)
1 The values are based on the set value.
The value is applied for a minimum pulse width of 1 ms.
Specifications