Instruction manual
Bulletin 700-HX
Plug-in Timing Relays
9-99
www.ab.com/catalogs Preferred availability cat. nos. are b
bold
.
Publication A117-CA001A-EN-P
Specifications
0
1
2
3
4
5
6
7
8
9
10
11
12
13
Characteristics1
Insulation Resistance
100 mΩ min. (at 500V DC)
Dielectric Strength
2000V AC, 50/60Hz for 1 min between current-carrying terminals and non-current-
carrying metal parts (1000V AC for 24V AC/12 to 24V DC type), 1000 VAC, 50/60 Hz for
1 min between non-continuous contacts
Noise Immunity
'+-1.5 kV (between power terminals) for 100 to 240 VAC, +-480V for 24VAC/12 to
24VDC, and +-600V (between input terminals), square-wave noise by noise simulator
(pulse width: 100 ns/1 μs, 1-ns rise)
Static Immunity ±8 kV (malfunction), ±15 kV (destruction)
Vibration Resistance Malfunction 10…55 Hz with 0.35 mm single amplitude each in three directions for 10 min
Shock Resistance Malfunction 98 m/s
2
(approx. 10 G) each in three directions
Life Expectancy
Mechanical 10 million operations min. (under no load at 18 000 operation/hr)
Electrical 100 000 operations min. (5 A at 250V AC, resistive load at 1800 operation/hr)
EMC
(EMI) EN61812-1
Emission Enclosure: EN55011 Group1 class A
Emission AC mains: EN55011 Group1 class A
(EMS) EN61812-1
Immunity ESD: EN61000-4-2: 4 kV contact discharge (level2) 8 kV air discharge (level3)
Immunity RF-interference: EN61000-4-3: 10 V/m
Enclosure Ratings
Panel surface:IP66 and NEMA Type 4X (indoors)
Weight Approx. 100 g
Certifications
CE Certified; cURus (File No. E14843, Guide NRNTZ/NRNT8), C-Tick Marked
Standards EN61010-1, EN 61326, VDE0106/P 100, CSA C22.2 No. 14, UL 508
1 700-HX User Manual, pub. number 700-UM002_-EN-D, available at Literature Library.
An attached waterproof packing is necessary to ensure IP66 waterproofing between the 700-HX and installation pan.