Specifications

ST900 Family General Handbook
667/HB/32900/000 Issue 11 Page 220 of 265
30.2 Stand-alone Pedestrian Controller Manual Panel
SIEMENS
CONT
PED
DEMAND
AUX 1 AUX 2 AUX 3
SW 1 SW 2 SW 3
PED 2
CABINET
ALARM
DFM
RESET
LAMP
TEST
SIGNALS
OFF
ON
CONT
VEHICLE
EXTEND
SELECT
VA
FVP
CONT
PED
DEMAND
PED 1
CONT
VEHICLE
EXTEND
SELECT
VA
FVP
Figure 40 – Stand-alone Pedestrian Controller Manual Panel
30.2.1 Continuous Pedestrian Demand
These buttons can be used to insert continuous pedestrian demands on the first
(PED1) or the second (PED2) stand-alone pedestrian stream. Pressing the button
toggles the state of the associated indicator. While the indicator is illuminated, an
artificial demand for the pedestrian phase is inserted.
For near-sided pedestrian crossings (i.e. those showing red during the clearance
period), an artificial on-crossing detect is inserted as required by TR2500 to extend
the clearance period to its maximum.