Specifications
  ST900 Family General Handbook 
667/HB/32900/000 Issue 12  Page 67 of 265 
  Common return cable for all BUT green aspect: 24W (6W+18W) at 
180 metres = 3 cores 
  Green aspect return cable 12W at 180metres = 2 cores 
4.  If required to minimise core usage it is permissible to common signal returns 
on the same pole as long as the total lamp load dependent on that return is 
considered and the cable length limitations defined in the table are observed. 
For example, two 12W RAG traffic signal heads require that a load of 24W is 
considered with a common return cable. (Note: please also consider the 
comments given in paragraph 1) 
5.  Regulatory signs should normally be cabled with a separate drive and return 
core. 
Where more than one regulatory sign is fitted to a pole, the drive and return 
for these may be common, as long as total load dependent on those cables is 
considered and the cable length limitations defined in the table are observed. 
If required to minimise core usage it is permissible to common regulatory sign 
and traffic signal returns on the same pole as long as the total load 
dependent on that return is considered and the cable length limitations 
defined in the table are observed. 
Example, assuming a distance of 100 metres using 1.0mm
2
 cable: 
  Reg Sign supply cable: 7W at 100 metres = 1 core 
  RAG traffic signal drive cables: 12W at 100 metres = 1 core each (x3) 
  RA + Reg Sign Common return cable: 19W (12W+7W) at 100 metres 
= 1 core. 
  Green return cable: 12W at 100metres = 1 core 
It should be noted from looking at the table that above 100 metres, 2 cores 
would be required for the 19W common return, and above 160 metres, 2 
cores would also be required for each 12W signal drive cable. 
6.  Tactile units are to be provided with a separate drive and return core. Tactile 
units driven from the same phase green LSLS output can share a common 
drive and return core. For the purposes of assessing acceptable cable run 