Specifications

3U Traffic Outstation Handbook
667/HB/26568/000 Page 166 Issue 15
* = Code only used in the fault log (FLG), not the current fault list (FLT)
= More details on these codes is provided in the subsections after this table
Code Description <Additional Parameters> - Notes
Absence Fault
VCF
Vehicle Classifier Confirm Fault <output action>
VCL*
Vehicle Classifier Licence Fault
VCP
Vehicle Classifier Vehicle
Presence Fault
<input no>
VCR
Vehicle Classifier Confirm Fault
Reset
<output action>
VLF
Vehicle Lamp Fault <phase> <colour> <no. of faults>
VLR*
Vehicle Lamp Replaced <phase> <colour> <no. of faults>
VPC
Vehicle Classifier Vehicle
Presence Fault Reset
<input no>
VPF
Vehicle Presence Fail (DFM) <input no>
WDG*
Watchdog timeout
WLF
Wait Lamp Fault <phase> <no. of faults>
WLR*
Wait Lamp Replaced <phase> <no. of faults>
XFC*
GEC CX Fault Cleared <GEC CX log no.>
XFL
GEC CX Fault Log entry <GEC CX log no.>
YPR*
Port Response returned
<phase> : Letter A to P, identifying the controller phase, as configured for this
OMCU
<stage> : A number 0 to 15, identifying the controller stage, as configured for
this OMCU
<no. of faults> : The number of uncleared lamp faults recorded on this sensor
<beacon ID> : The configured beacon/reader identity number
<alt max no.> : The controller alternative max. green set number (1 to 3)
<sign ID> : The sign identity number as configured in the OMCU lamp
monitoring data
<GEC CX log no.> : Controller fault log number, refer to CX controller handbook
<Siemens log no.> : Controller fault log number, refer to T200/T400/ST800 controller
handbook
<Microsense mnemonic> : three-character fault mnemonic as read from the
Microsense controller fault log
<radio clock error type> : 0 = No logic level signal detected from the radio clock on
the configured OMCU input
1 = Radio clock is indicating reception quality is poor
2 = Noise/corruption detected on the logic level signal
from the radio clock
See also RCS on page 185.
<plan no> : A number 0 to 15, identifying the plan number