Specifications
3U Traffic Outstation Handbook
667/HB/26568/000 Page 179 Issue 15
11.8 MAINTENANCE COMMAND TABLE
CODE
MAJOR
INDEX
MINOR
INDEX
DATA
RANGE DESCRIPTION AND REMARKS
ACCESS
LEVEL
BAS
- - 0 - 2
Handset Display Base:
0 = Binary, 1 = HEX, 2 = Decimal
open
CAL
- - 0 - 1
Call Instation:
Request local dial-back using
configured telephone numbers.
Write 1, OMCU responds with 0
when actioned
Maint
CBR
- - 0, 101 -
105
Controller Baud Rate:
Overrides configured setting when
monitoring CX controller:-
0 = 1200 baud (default)
101 = 300 baud
102 = 1200 baud
103 = 2400 baud
104 = 4800 baud
105 = 9600 baud
Maint
CFD
- - 0 – 10
Controller Fault Debounce:
Delays reporting a fault from the
controller until it has been
received n times (0 – 10). 0 means
no debounce needed ie. fault
logged on first occurrence.
Maint
EBR
- - 0 - 31
Engineering Base segment for
RAM display
Segment = EBR value x 10000H
open
EEL
(PB680
issue 8
or later)
- - 0 - 255
Examine Enhanced 141 Link to
the ST800, values are:-
0 = Not configured
1 = Connecting
2 = Checking ST800 (1200 baud)
3 = Link active (19200 baud)
254 = Old ST800 firmware
255 = Controller not detected (link
out/power off)
RO
ENR
0 -FFFF - ENG
Engineering RAM Display
Starting segment defined by EBR
command
RO
ERR
-
- -
Enable Restart Reports:
0=Disable, 1=Enable
Maint